Action Instruments Product Categories

Action Instruments Product Categories

  • Sheet Metal Surface Quality Tester MRP29HY

    Sheet Metal Surface Quality Tester | MRP29HY

    Sheet Metal Surface Quality Tester - Overview

    The Sheet Metal Surface Quality Tester MRP29HY can measure surface quality and the efficiency in surface conditions of sheet micro-ohmmeter metals/plates. The MRP29HY consists of a micro-ohmmeter and a hydraulic press and the engineering principle is based on the ‘German Association for Welding Technology E.V.’ data sheet for quality evaluation on the sheet metal which is vital for every application, where the reliability is dependent on the surface quality. The priority is the welding of sheet metal (e.g. after etching, and brushing) in the automotive and aircraft industry, but also surface treatment (e.g. lacquer and splicing). The MRP29HY can measure the contact resistance on single sheet metal or overlap sheet metal e.g. aluminum or corresponding alloy, and other materials.

    Datasheet

  • Network Analyser

    3 Phase Network Analyzer with DIN Display | UPM309RGW

    3 Phase Network Analyser with Rogowski coils - Overview

    UPM309 is an innovative instrument for the measurement and recording of electrical power parameters. It is particularly suitable for consumption analysis and control, with an excellent quality/price ratio. Connections are quick and easy, useful for retrofitting applications on existing switchboards or for an energy audit.

    UPM309 is the ideal instrument to establish the measurement points on the plant. The instrument communicates with an RS485 serial port by MODBUS RTU/ASCII protocol or through an Ethernet port by MODBUS TCP protocol.

    Furthermore, it is available with WintoolNET software for remote management. The web interface is also available with an Ethernet port option: a very useful function that gives the option to manage the instrument by any PC connected to the network.

    3 Phase Network Analyser with Rogowski coils - Features

    • DIN 96x96 ultra-compact version, only 39 mm depth
    • Fully bi-directional four quadrants measurements for all energies and powers
    • Up to 24 parameters selectable among real-time measurements for MIN/AVG/MAX recording (ENH version)
    • Main electrical parameters measured and displayed for a cost-effective consumption analysis
    • 4 available KITs: 30, 45, 70, 90 cm
    • 3 selectable current scales
    • Possibility to connect by PT
    • Up to 8 MB for data recording (ENH version)
    • Record all energy counters (ENH version)
    • MODBUS RTU/ASCII communication by RS485 port
    • MODBUS TCP communication by Ethernet port
    • Possibility to manage the instrument in remote mode by WintoolNET software or by the Web server interface
    • 2 digital outputs, 1 digital input, 1 analogue output (optional)
  • Electrical Installation Meter with Power Analyzer | MPI-540

    Safety Rating CAT III at 500V LabelSafety Rating Cat IV at 300V labelLi-Ion Battery labelIP51 LabelBluetooth labelWiFi label

    Electrical Installation  Meter - Overview

    The MPI-540 meter is designed for checking the safety of industrial and domestic electrical installations. The user has the option to register the parameters of electrical networks located at these facilities. This allows for the measurement of the parameters for protection against electric shock using a single universal device while verifying the quality of electricity. The Auto mode allows significant automation of measurements of the meter and makes it possible to test the functioning of residual current circuit breakers, as well as in pre-programmed measuring sequences, which can be extended with their own sequences. Automatic measurement of insulation resistance of 3-, 4- and 5-wire conductors is possible by using an additional AUTO ISO-1000C adapter.

     

  • Power Quality Analyzer PQM3000

    Power Quality Analyzer | PQM3000

    Power Quality Analyzer PQM3000 - Overview

    The PQM3000 is a high-end power quality analyzer which is able to monitor and record the major power quality parameters. It provides accurate measurement and voltage characteristics are monitored according to Class A specifications. It can also act as an event/fault recorder, capable of storing a high number of voltage events and disturbances, frequency variations, inrush current, etc. Additional PQ data can be recorded, such as Flicker, Unbalance, Harmonics and Interharmonics, and Mains Signalling. It also provides standard power measurement data for three-phase systems. Extra voltage and current measurement channels allow additional monitoring of Neutral Potential and Earth Leakage current.

    PQM3000 is available for external standard CTs with 1 or 5A output. In this way, maximum flexibility is granted even in existing plants.

    The powerful recording features can capture and record all types of standard and PQ data simultaneously. This can be recorded for a long time due to the high memory capacity. In this way a complete EN 50160 analysis can be performed. Events and disturbances also provide waveform recording together with RMS values. Recordings can be transferred directly through a web interface or set as an automatic scheduled data upload to a remote server.

    PQM3000 includes different communication ports so the user can access them in different ways. The Ethernet ports on the front and rear panels allow complete control on the instrument such as web access for real-time monitoring, device setup, stored data transfer, and maintenance operations. The external mobile network router gives the possibility to manage the device via a 4G network if the Ethernet communication is not available (router sold separately). The RS485 port is dedicated to the data reading of PQMGPS1, i.e. the external GPS module provided with the instrument. PQMGPS1 provides accurate time information regardless of the location of the installation in a distributed monitoring system.

    Moreover, different I/O channels are provided to enhance the instrument features. A user-friendly multilingual interface is provided for the webserver which simplifies access to instrument functions.

    Power Quality Analyzer PQM3000 - Features

    • Rack 19” mounting
    • Harmonics and inter-harmonics measurement
    •  Data recording for further EN 50160 analysis
    • Data recorded in standard PQDIF and CSV file formats
    • Embedded web server
    • Communication on Ethernet and 4G networks
    • Included external GPS module for accurate timing
    • Internal rechargeable backup battery
    • Certified according to IEC/EN 61000-4-30:2015 Ed.3
    • Class A for voltage characteristics

    DATASHEET

  • Selective Level Meter | SLM 3505

    Selective Level Meter - Overview

    The Selective Level Meter SLM3505 was designed to provide a single-instrument solution for the Electric Utility System Protection Engineers and Relay/Communications Technicians responsible for the alignment and maintenance of Power Line Carrier, Audio Tone, and FSK Communications Systems. This multifunction instrument replaces all 4 existing Power Line Carrier Instruments for a fraction of the cost. All in a compact lightweight package.

    Selective Level Meter SLM 3505 Features

    • Frequency range 5Hz to 5MHz
    • Selectable inputs up to 300 Vpk
    • Low and High-level generators
    • Dual-frequency SLM mode
    • Impedance analyzer
    • VSWR Meter
    • Oscilloscope mode
    • Line trap/tuner test
    • Mains / 12 volt dc / internal battery operation
    • Supplied complete with rugged flight case
  • Winding Resistance Transformer and Motor Meter MR8050

    Winding Resistance Transformer and Motor Meter | MR 8050

    Winding Resistance Transformer and Motor Meter - Overview

    The MR8050 can measure highly inductive windings of transformers, motors, and reactors with a range of 100µΩ with 0.01µΩ resolution up to 6kΩ. The performance of the measured objects can be up to 800MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V), this is important for time-critical measurements (cooling curves).  The unloading of the transformer's core is fast and safe, as the energy is dissipated in the MR8050. The temperature of the measured objects can be pre-set or measured using a PT100 temperature sensor and the resistance is calculated for 20°C using the temperature coefficient for copper or aluminum heat-loss measurements. The resistance at t=0 (disconnection of load) is shown as a result of the internal regression algorithm. Two windings (mostly HV and LV) can be measured simultaneously in the DUAL measuring method. The MR 8050 also features automatic tap-changer control for measuring different taps without interrupting the measuring current.

    Winding Resistance Transformer and Motor Meter - Features

    • 2 channels for DUAL measurements
    • Measuring time short due to very fast uploading
    • Discharge time 1/10 of uploading time
    • Heat - loss measurements with regression algorithm
    • LCD-Display with 240 x 128 pixels with backlight
    • USB standard and RS232C 9600 baud
    • PT100 connector for PT100 temperature probe
    • Tap changer connector for automatic tap control
    • Warning system connector for a separate warning light
    • Internal test storage for up to 1000 measurements
    • Inputs full protected against static and transient voltages
    • Wide current ranges from 50mA to 60A

    Datasheet

  • Advanced Three-Phase Winding Resistance Meters | TWA Std Series

    Advanced Three-Phase Winding Resistance Meters - Overview

    The TWA Standard series has LCD displays. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetisation. The stored magnetic energy is safely and automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilisation criteria. Both models can output test currents from 5 mA to 30 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronisation of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with a 0.1 ms sampling rate, simultaneously with the measurement of the tap changer motor current, which helps with the detection of motor and mechanical issues. An algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test, simultaneously with the winding resistance test in all tap positions.

    Advanced Three-Phase Winding Resistance Meters  - Features

    • Resistance measurement of all tap positions in all six windings performed in a single test
    • True three-phase on-load tap changer (OLTC) DVtest (dynamic resistance measurement)
    • Quick measurement, single-step cable setup
    • Rapid automatic demagnetisation
    • Fully automated test mode
    • Built-in tap changer control unit
    • Temperature measurement channel

    https://www.youtube.com/watch?v=aUJ0BNudhI4

  • Three Phase Transformer Measuring Bridge | MLS 7100

    Three-Phase Transformer Measuring Bridge - Overview

    The MLS 7100 was particularly designed to simplify the determination of transformer core and copper losses, which is an ideal choice when working on site. The measuring bridge features open-circuit as well as short-circuit measuring. Many transformers can be directly connected to the MLS 7100 without needing further transducers. Core losses are an important transformer quantity in electrical efficiency, operating expenses, and the overall transformer value.

    Steel losses are typically determined using open-circuit measurement, as a relatively small magnetising current is flowing. Using this technique, the copper losses are minimized due to the square correlation of power and current. Copper losses are determined using short circuit measurement, as the magnetising modulation of the steel core should be minimized. In addition, the short circuit voltage is determined this way, which is also an important quantity.

    Three Phase Transformer Measuring Bridge - Features

    • Open circuit measurements
    • Short circuit measurements
    • Free selectable voltage and current dividers
    • 1000 kV with transducer
    • 1000 kA with transducer
    • 550 V (chained) 6 A directly connectable
    • Measures and displays:
      • Voltages
      • Currents
      • Power
      • Short Circuit Values
      • Frequency
    • Centronics printer port
    • RS232C port for external control

    Datasheet

  • Three-Phase Transformer Turns Ratio Tester PWR3A

    Three-Phase Transformer Turns Ratio Tester | PWR3A

    Three-Phase Transformer Turns Ratio Tester - Overview

    The great advantage of the Three-Phase Transformer Tester PWR3A is its simple set-up. You simply type in the vector group with the keys to set up, connect the transformer to the device, and release the measurement. All three phases are measured consecutively. All connecting and short-circuited procedures at the primary and secondary voltage sides are performed automatically before each measurement. It is also possible to measure just one phase. An adjustable set value allows an error or deviation of the measured transformation ratio to be displayed. Automatic control of the tap changer is provided. All phases and taps are measured consecutively, and the results are stored inside the instrument and transferred to a PC. The transformer-specific data can be easily programmed via a connected PC but it is also possible via the internal keyboard. The  PWR3A is connected to the H.V. and L.V. sides via four connections each. It also powers the test object at a selected voltage, supplied by an internal isolating transformer. An external excitation using different voltages and frequencies is also possible.

    Three-Phase Transformer Turns Ratio Tester - Features

    • Ratio range from 0.75 to 20,000 (higher ratios with CVT-Ext.)
    • Fully automated measurement
    • Features market unique Vector Group Detection
    • Measuring voltage from 8 V to 230 V
    • Measuring voltage up to 5 kV by CVT-Extension: PWR3A-CVT
    • Using 3-phase voltage for phase angles other than 0°/180°
    • Easy to handle tap changer automatic
    • Internal memory stores all dates (Reading with PWR3A-XFER)
    • LC display (256 x 128 pixel) with backlight
    • Easy input of vector group and measuring conditions
    • USB/RS232C port to get full instrument control
    • Centronics printer port or built in printer (optional)
    • Robust mobile case for field use
    • Factory Certificate

    Datasheet

  • Power Quality Analyzer PQM-702

    Power Quality Analyzer PQM-702

    Safety Rating Cat IV at 600V labelIngress protection IP65 labelGPS

    Power Quality Analyzer - Overview

    The Power Quality Analyzer PQM-702 is a high-tech device providing users with features to measure, analyze and record parameters of 50/60 Hz power networks and power quality in accordance with the European Standard EN 50160. Analyzers are fully compliant with the requirements of IEC 61000-4-30:2015, Class A.

    The device is equipped with five voltage measurement inputs installed as cables terminated with banana plugs marked as L1/A, L2/B, L3/C, N and PE (ground). The voltages measured by four measurement channels are up to ±1500V (the device has two voltage sub-ranges). This range may be increased by using additional external voltage transformers. Current is measured using four inputs installed on short cables terminated with probe terminals. The terminals may be connected to the following probe types: flexible claps (marked as F-1(A), F-2(A), F-3(A)) with nominal rating up to 3000 A (differing from others only by coil diameter); clamps F-1A6, F-2A6, F-3A6 with a nominal range up to 6000 A and hard probes marked as C-4 (range up to 1000 A AC), C-5(A) (up to 1000 A AC/DC), C-6(A) (up to 10 A AC) and C-7(A) (up to 100 A AC). The values of nominal measured currents may be changed by using additional transducers – for example, using a transducer of 1000:5 ratio, the user may select C-6(A) probes to measure currents up to 1000 A

    Power Quality Analyzer - Features

    • Power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760V
    • Emphasis on measurements at low voltage poles, due to the ease of connection
    • Independent power supply socket suited for voltage measurements for transformers and DC circuits
    • Remote control and data transfer through a built-in GSM modem (GPRS)
    • Anti-theft feature - SMS notification in the event of position change - built-in GPS receiver
    • Real-time clock synchronized to GPS protocol
    • Measurements according to EN 50160
    • Voltage L1, L2, L3, N, PE
      • average, minimum, maximum and instantaneous values, range to 760 V, ability to work with voltage transformers
    • Current L1, L2, L3, N (four inputs)
      • average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp)
      • ability to work with current transformers
    • Crest factor for voltage and current
    • Frequency from 40 Hz to 70 Hz
    • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive)
    • Power recording:
      • Budeanu method
      • IEEE 1459
    • Active, reactive, apparent energy
    • Power factor, cosφ, tgφ
    • K factor (transformer overload caused by the harmonics)
    • Up to 50th harmonics for voltage and current
    • Total Harmonic Distortion (THD) for voltage and current
    • Short-term (PST) and long-term (PLT) flicker
    • Unbalance of voltage and current
    • Current events detection including waveforms recording
    • Current and voltage waveforms recording after each averaging period
  • Dielectric Oil Breakdown Voltage Flash Point Tester | PORTATEST A-2

    Oil Dielectric Breakdown Voltage Tester - Overview

    The PORTATEST A-2 Oil tester is a fully automatic tester for the determination of the dielectric breakdown voltage of the insulating liquid. Otherwise known as a flashpoint tester. It has been designed for laboratory use as well as field use for servicing and commissioning. The PORTATEST A-2 is very comfortable and easy to use. The requested testing standard may be selected via the menu. The corresponding electrode type as well as the electrode spacing will be displayed for confirmation before starting the test. After placing the test vessel with the oil sample into the test chamber, the protection lid needs to be closed. For maximum operator security, the protection lid is equipped with a security interlock key switching off the HV when opened during testing. When starting the test, sample temperature as well as a customer-specific sample number may be entered and will then be integrated into the test report printout. The testing sequence according to the selected testing standard is performed fully automatically.

    Oil dielectric breakdown voltage tester - Features

    • Fully automatic Oil tester for laboratory and field use during service and commissioning
    • Testing voltage up to 100 kV
    • Pre-Programmed for common national and international testing standards
    • Up to ten free programmable user testing sequences
    • Short switch-off time <1ms avoiding carbonization of the sample
    • Indication of individual breakdown values, average value, and standard deviation
    • Graphic-Display with backlight
    • Clear operator guiding via four soft keys F1 - F4
    • Input dialogue for sample temperature and sample number if required
    • Multi-language menu, language selected via the Setup menu
    • PC-data storage via serial interface RS232
    • Glass test vessel with a lid and magnetic stirrer
    • Different electrodes available (mushroom, sphere, or disc)
    • Electrode spacing adjustable
    • Integrated printer
    • Rugged aluminium housing with shielded test chamber
  • Handheld Turns Ratio Tester TRT-H

    Handheld Turns Ratio Tester | TRT-H

    Handheld Turns Ratio Tester  - Overview

    The TRT-H is a battery operated, handheld, fully automatic test set designed for turns ratio, excitation current and phase shift measurements of transformers. The transformer turns ratio is determined by applying AC voltage across high-voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. The user can enter a transformer’s nameplate voltages, so that the turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. It compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Applications include: Turns ratio measurement of distribution transformers; Turns ratio verification of instrument transformers; Turns ratio deviation calculation; Excitation current measurement of distribution and instrument transformers; Phase angle measurement of distribution and instrument transformers; and Polarity check of instrument transformers.

    Handheld Turns Ratio Tester - Features

    • Unique handheld instrument
    • Extremely lightweight – only 1.4 kg / 3.1 lbs
    • Measures 3 transformer parameters:
      • Turns ratio
      • Excitation current
      • Phase angle
    • Single-phase test voltage up to 40 V AC
    • Turns ratio accuracy up to ±0.1%
    • Battery-powered
    • Tests single-phase and three-phase transformers

     

  • Power Quality Analyzer PQM-703

    Safety Rating Cat IV at 600V labelIngress protection IP65 labelGPS

    Power Quality Analyzer - Overview

    Power Quality Analyzers PQM-703 include all features of the PQM 702 but with extra functionality: mains signalling up to 3000 Hz, Transients up to ±6000 V, and minimal transient capturing time of 650 ns. This technically advanced product allows for comprehensive measurements of the quality of electricity, analysis and recording of power network parameters for frequencies 50/60 Hz, all in accordance with the European Standard EN 50160. Analyzers are fully compliant with the requirements of IEC 61000-4-30:2015, Class A.

    The device is equipped with five voltage measurement inputs installed as cables terminated with banana plugs marked as L1/A, L2/B, L3/C, N and PE (ground). The voltages measured by four measurement channels are up to ±1500V (the device has two voltage sub-ranges). This range may be increased by using additional external voltage transformers. Current is measured using four inputs installed on short cables terminated with probe terminals. The terminals may be connected to the following probe types: flexible claps (marked as F-1(A), F-2(A), F-3(A)) with nominal rating up to 3000 A (differing from others only by coil diameter); clamps F-1A6, F-2A6, F-3A6 with a nominal range up to 6000 A and hard probes marked as C-4 (range up to 1000 A AC), C-5(A) (up to 1000 A AC/DC), C-6(A) (up to 10 A AC) and C-7(A) (up to 100 A AC). The values of nominal measured currents may be changed by using additional transducers – for example, using a transducer of 1000:5 ratio, the user may select C-6(A) probes to measure currents up to 1000 A

    Power Quality Analyzer - Features

    • Mains signalling up to 3000 Hz
    • Transients up to ±6000 V, minimal transient capturing time is 650 ns
    • All parameters meet Class A acc. IEC 61000-4-30 standard
    • Measurements according to EN 50160
    • Voltage L1, L2, L3, N-PE
      • average, minimum, maximum and instantaneous values
      • range to 760 V
      • ability to work with voltage transformers
    • Current L1, L2, L3, N (four inputs)
      • average, minimum, maximum and instantaneous values
      • measurement current with range to 3 kA (depends on used clamp)
      • ability to work with current transformers
    • Crest factor for voltage and current
    • Frequency from 40 Hz to 70 Hz
    • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive)
    • Power recording:
      • Budeanu method
      • IEEE 1459
    • Active, reactive, apparent energy
    • Power factor, cosφ, tgφ
    • K factor (transformer overload caused by the harmonics)
    • Up to 50th harmonics for voltage and current
    • Total Harmonic Distortion (THD) for voltage and current
    • Short-term (PST) and long-term (PLT) flicker
    • Unbalance of voltage and current
    • Current events detection including waveforms recording
    • Current and voltage waveforms recording after each averaging period
  • Thermal Imager KT-145

    Thermal Imager | KT-145

    Thermal Imager - Overview

    This is a robust and handy high-tech Thermal Imager. Its intuitive handling and user-friendly single-hand operation make it easy to use. The long battery life makes it an ideal tool for troubleshooting electrical installations, mechanical components, buildings management, process equipment, HVAC/R equipment and others.

    Thermal Imager - Features

    • Removable large capacity Li-ion battery
    • 4-hour working time
    • Friendly UI, easy to use without training
    • Affordable as an entry-level diagnostic tool
    • 3,5'’ screen with no image cropping
    • High brightness screen
    • Rugged and compact design, metal internal structure
    • Standard Micro USB interface for data transmission and charging
    • Wi-Fi connection (Optional)
  • Thermal Image Camera | KT-200

    Thermal Image Camera - Overview

    The KT-200 thermal camera has a resolution of 192x144 pixels. Its wide temperature measurement range and high-quality lenses guarantee a high level of detail and accuracy in the recorded images. The cameras in this series are available in several variants allowing you to choose the right option for your particular requirements. It is compact and has a large display and is easy to use. The navigation button is supported by a menu on the touchscreen. This model ensures simple and intuitive operation. It not only acts as a Thermal imager as its camera is equipped with visual lenses and related image mixing technologies: PIP, and MIF. Support from the built-in LED torch and laser improves operational quality by facilitating photography and then image interpretation. The built-in report module allows for the preparation and printing out of reports directly from the camera. Built-in communication interfaces ensure constant communication between the camera and the computer or mobile device, also over a wireless network. An ideal tool for both novice users and professional thermographic inspectors.

    Thermal Image Camera - Features

    • high sensitivity of detectors and a wide temperature range
    • comprehensive image analysis tools
    • intuitive user interface
    • IR video recording (on the SD card or computer disc)
    • built-in report module
    • different imaging modes: IR, visual, PIP, MIF
    • built-in visual camera: 5 Mpx
    • built-in: LED torch, laser pointer
    • interfaces: Micro USB2.0, Wi-Fi, Gigabit Ethernet, Mini HDMI, slot microSD