Category: Insulation Resistance Meters

Insulation Resistance Meters

Insulation Resistance Meters are used for predictive or preventative maintenance programs. Also known as megohmmeters they are designed to identify potential equipment failures before they occur. Insulation resistance testers are perfect for testing a wide range of high voltage equipment including motors, switchgear, generators, and cables.

  • 15kV Insulation Resistance Meter | MIC15k1

    Call for price

    Bluetooth labelIP67 LabelIP40 Label

    15kV Insulation Resistance Meter - Overview

    The MIC-15k1 meter is designed to measure the insulation resistance of power objects up to 15kV, i.e. single and multicore cables, transformers, motors and generators, capacitors, switches, and other devices installed in power stations. It is especially recommended for measurements in areas with very high electromagnetic disturbances, e.g. electrical substations with 1200 kV AC and 500 kV DC. Thanks to the 15 kV measuring voltage (in accordance with ANSI / NETA ATS-2009 TABLES 100.1) the meter can be used for measuring objects with a nominal voltage above 34.5 kV.

    15kV Insulation Resistance Meter - Features

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, and DD, widened with the partial discharge (PD) indicator for each of these measurements
    • Testing the electrical durability of tested object - breakdown voltage indication
    • High resistance to electromagnetic interferences - uninterrupted work in power stations & close to high voltage transmission lines up to 1200 kV AC & 500 kV DC
    • Smooth voltage rise in time function (RT - Ramp Test) - state the partial discharges in the facility and carry out a partial location of their occurrence
    • Efficient converter with a power of ~150 W enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length)
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate the direction of the fault (the conductor must be buried in the ground with earth direct contact)
    • Compatible with external software
  • Dielectric Oil Breakdown Voltage Flash Point Tester PORTATEST A-2

    Dielectric Oil Breakdown Voltage Flash Point Tester | PORTATEST A-2

    Call for price

    Oil Dielectric Breakdown Voltage Tester - Overview

    The PORTATEST A-2 Oil tester is a fully automatic tester for the determination of the dielectric breakdown voltage of the insulating liquid. Otherwise known as a flashpoint tester. It has been designed for laboratory use as well as field use for servicing and commissioning. The PORTATEST A-2 is very comfortable and easy to use. The requested testing standard may be selected via the menu. The corresponding electrode type as well as the electrode spacing will be displayed for confirmation before starting the test. After placing the test vessel with the oil sample into the test chamber, the protection lid needs to be closed. For maximum operator security, the protection lid is equipped with a security interlock key switching off the HV when opened during testing. When starting the test, sample temperature as well as a customer-specific sample number may be entered and will then be integrated into the test report printout. The testing sequence according to the selected testing standard is performed fully automatically.

    Oil dielectric breakdown voltage tester - Features

    • Fully automatic Oil tester for laboratory and field use during service and commissioning
    • Testing voltage up to 100 kV
    • Pre-Programmed for common national and international testing standards
    • Up to ten free programmable user testing sequences
    • Short switch-off time <1ms avoiding carbonization of the sample
    • Indication of individual breakdown values, average value, and standard deviation
    • Graphic-Display with backlight
    • Clear operator guiding via four soft keys F1 - F4
    • Input dialogue for sample temperature and sample number if required
    • Multi-language menu, language selected via the Setup menu
    • PC-data storage via serial interface RS232
    • Glass test vessel with a lid and magnetic stirrer
    • Different electrodes available (mushroom, sphere, or disc)
    • Electrode spacing adjustable
    • Integrated printer
    • Rugged aluminium housing with shielded test chamber
  • Insulation Resistance Meter 15TΩ MIC-5010

    Insulation Resistance Meter 15TΩ | MIC-5010

    Call for price

    Insulation Resistance Meter 15 TΩ - Overview

    This resistance meter is a reliable tool for measuring insulation resistance up to 15 TΩ. The maximum measurement current is 1.2 mA or 3 mA, which guarantees the charging of an object with a large capacity in a short time. Each measurement, either when the programmed time expires or is manually interrupted, ends with the meter discharging the object. The device has unique algorithms that allow it to recognise the nature of the voltage present on an object, enabling the instrument to determine whether the voltage is the mains voltage or whether it is the voltage generated by an electromagnetic field. This makes it possible to carry out measurements in the presence of very strong electromagnetic fields where this was previously not feasible.

    The instrument is equipped with accessories that guarantee safety during measurements with all available voltages - test leads, probes, and crocodile clips meet extremely rigorous standards. The accessories are supplied as standard with a handy carrying case. The high resistance of the device to interference means that cables as long as 20 m can be used for measurements.

    Insulation Resistance Meter 15 TΩ - Features

    • Voltage range of 50…5000 V, 50…1000 V in steps of 10 V, 1…5 kV in steps of 25 V
    • Continuous indication of insulation resistance and leakage current
    • Automatic discharge of measured object capacitance voltage after measurement
    • Acoustic signaling of 5-second intervals for capturing time characteristics
    • Adjustable measuring time - max. 99'59'’
    • Metered T1, T2, and T3 test times
    • Measurement of coefficients: polarisation (PI), absorption Ab1, Ab2, dielectric absorption ratio (DAR)
    • Indication of actual test voltage during measurement
    • Test current: 1.2 mA or 3 mA
    • Two- and three-lead method of insulation resistance measurement
    • Measurements with test leads up to 20 m
    • Protection against measuring live objects
    • Measurement of capacitance during the measurement of RISO
    • Step voltage insulation resistance measurement (SV)
    • Dielectric Discharge calculation (DD)
    • Digital filters for measurements with strong interferences
    • Continuity measurement of protective connections & bonding in accordance with EN 61557-4 with current > 200 mA
    • Adjustable limits for measured insulation resistance
    • Adjustable limits for measured RCONT resistance
    • Measurement of leakage current during insulation resistance testing
    • DC and AC voltage measurement in the range of 0…600 V
    • 990 cells of memory (11880 records)
    • Wireless data transmission via Bluetooth or USB cable
    • Power supply from mains or battery pack
    • Backlit display
    • Backlit keys
    • Meets EN 61557 standard

     

  • Multi-function Electrical Installation Meter MPI-540

    Electrical Installation Meter with Power Analyzer | MPI-540

    Call for price

    Safety Rating CAT III at 500V LabelSafety Rating Cat IV at 300V labelLi-Ion Battery labelIP51 LabelBluetooth labelWiFi label

    Electrical Installation  Meter - Overview

    The MPI-540 meter is designed for checking the safety of industrial and domestic electrical installations. The user has the option to register the parameters of electrical networks located at these facilities. This allows for the measurement of the parameters for protection against electric shock using a single universal device while verifying the quality of electricity. The Auto mode allows significant automation of measurements of the meter and makes it possible to test the functioning of residual current circuit breakers, as well as in pre-programmed measuring sequences, which can be extended with their own sequences. Automatic measurement of insulation resistance of 3-, 4- and 5-wire conductors is possible by using an additional AUTO ISO-1000C adapter.

     

  • Mega Ohm Meter | MIC-10

    R6,712.00

    Safety Rating Cat IV at 600V label Safety Rating Cat III at 1000V labelIngress protection IP67 label

    Mega Ohm Meter - Overview

    The MIC-10 meter is designed to perform electrical tests, which establish the safety of insulation in systems. This is a very handy digital multimeter tool,  measuring insulation resistance up to 10GOhms with up to 1000V measuring in accordance with IEC61557-2.

    Mega Ohm Meter - Features

    • Continuous indication of insulation resistance or leakage current
    • Select test voltages of: 50, 100, 250, 500, 1000 V
    • Automatic discharge of capacitance of tested object after the insulation resistance measurement
    • Acoustic signalling of five-second periods to facilitate obtaining time characteristics
    • Indication of actual test voltage during the measurement
    • Protection against measuring live objects
    • Three-lead measurement
    • Continuity measurement of protective and equipotential conductors according to EN 61557 - 4 with  >200 mA current
    • Low-voltage circuit continuity and resistance measurement
    • Circuit resistance measurement (<1999 ) with the <15 mA current
    • Sound signal if circuit resistance is below 30Ω
    • Capacitance measurement during the RISO measurement
    • Measurement of alternating and direct voltages in the 0...600 V range
    • Power supply: 4 AA disposable or rechargeable batteries, monitoring of power supply voltage
    • Meter conforms to EN 61557
  • 10kV Insulation Resistance meter up to 40 Tera-Ohm | MIC10k1

    Call for price

    IEC 61557 label Safety Cat IV at 600V label Safety Cat III at 1000V label Bluetooth Enabled label Ingress protection IP40 label

     

    10kV Insulation Resistance meter - Overview

    This insulation resistance meter has a digital filter function for measurements in a high-noise environment. Continuity measurement of protective connections and equipotential bonding in accordance with EN 61557-4 with current > 200 mA.  Adjustable limits for measured resistance RISO and RCONT. Measurement of leakage current during insulation resistance testing. DC and AC voltage measurement in the range of  0...750 V. Drawing graphs on the display during measurement. Innovative memory with the option to describe measurement points, facilities, and names of customers. Can be operated with a mini Bluetooth keyboard (optional). Stable measurements in noisy environments such as 765 kV substations. Graphic LCD 5,6'’ backlit display. Keyboard backlit. Power supply from battery packs. Built-in fast charger. The instruments meet the requirements of the EN 61557 standard.

    10kV Insulation Resistance meter - Features

    • clear visible display
    • measurement voltage in the range of: 50…10000 V (50...1000 V at 10 V and 1...10 kV at 25 V)
    • continuous indication of measured insulation resistance or leakage current
    • automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement
    • acoustic signalling of 5 seconds intervals to facilitate capturing time characteristics
    • adjustable measuring time to 99'59'’
    • metered T1, T2 and T3 test times for measuring one or two absorption coefficients from the range of 1…600 s
    • polarization index (PI), absorption coefficients Ab1, Ab2 and dielectric absorption ratio (DAR) measurement
    • indication of actual test voltage during measurement
    • 1.2 mA, 3 mA and 5 mA test current
    • insulation resistance measurement using two- or three-wire method
    • measurements with test leads up to 20 m
    • protection against measuring live objects
    • automatic measurement of multiple core cables with the additional AutoISO-5000 adapter (for MIC-10k1 max. voltage 5 kV)
    • measurement of capacitance during the measurement of RISO
    • measurement of temperature (with additional probe - WASONT1)
    • step voltage insulation resistance measurement (SV)
    • Dielectric Discharge calculation (DD)
    • location of damage (burnout)

    https://www.youtube.com/watch?v=ibX7f55ngzc

     

  • Multi-function Electrical Installation Meter | MPI-540

    Call for price

    Multi-function Electrical Installation Meter - Overview

    The MPI-540 meter is designed for checking home and industrial electrical installations. Measurements taken by this device determine the safety of the installation. The user also has the option to register the parameters of the electrical network's location.

    Verification of the quality of electricity and measurement of the parameters that protect against electric shock is easy with this single, universal device. This superior meter combines the measurement capabilities of several devices while ensuring quality and accuracy. Significant automation of measurements with the meter makes it possible to test functioning of residual current circuit breaker in the auto mode, as well as in pre-programmed measuring sequences (so-called auto-tests), which can also be extended with your own sequences. Automatic measurement of insulation resistance of 3-, 4- and 5- wire conductors is possible by using additional the AUTO ISO-1000C adaptor.

    This device is ideal for all measurements for the commissioning of electrical installations in accordance with applicable regulations.

    Multi-function Electrical Installation Meter - Features

    • 7 " TFT LCD touch screen with a resolution of 800 x 480 pixels
    • Removable memory card - easy increase of memory capacity
    • One device can be used for all measurements for commissioning of electrical installations in accordance with applicable regulations:
      • short circuit loop impedance (also in circuits with RCDs)
      • parameters of RCDs
      • insulation resistance
      • earthing resistance (4 measurement methods + ground resistivity measurement)
      • continuity of protective and equipotential bondings
      • lighting measurement
      • phase sequence tester
      • motor rotation direction tester
    • three-phase power network data logger can record 50/60 Hz power network parameters in acc. to S class of EN 61000-4-30:
      • voltage L1, L2, L3, - average values in the range up to 500 V,
      • L1, L2, L3 currents, - average values, current measurement in the range up to 3 kA (depending on the current clamps used)
      • frequency in the range of 40Hz - 70Hz
      • active (P), reactive (Q) and apparent (S) power
      • power factor (PF), cosφ
      • harmonics (up to 40 in voltage and current)
      • total harmonic distortion (THD) for current and voltage
  • Insulation Resistance Meter 5kV MIC-5050

    Insulation Resistance Meter 5kV | MIC-5050

    Call for price

    IEC 61557 label Safety Cat IV at 600V label Safety Cat III at 1000V label Bluetooth Enabled label Ingress protection IP40 label

    Insulation Resistance Meter 5kV - Overview

    This insulation resistance meter has a digital filter function for measurements in high-noise environments.  Continuity measurement of protective connections and equipotential bonding in accordance with EN 61557-4 with current > 200 mA.  Adjustable limits for measured resistance RISO and RCONT. Measurement of leakage current during insulation resistance testing. DC and AC voltage measurement in the range of  0...750 V. Graphs on the display during measurement. Innovative memory with the option to describe: measurement points, facilities, and names of customers. Bluetooth keyboard (optional). Graphic backlit LCD 5,6'’. Keyboard backlit. Power supply from a main power line or battery packs. Built-in fast charger. The instruments meet the requirements of the EN 61557 standard.

    Insulation Resistance Meter 5kV -Features

    • measurement voltage any in the range of 50...5000 V (50...1000 V at 10 V and 1...5 kV at 25 V)
    • continuous indication of measured insulation resistance or leakage current
    • automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement
    • acoustic signalling of 5 seconds intervals to facilitate capturing time characteristics
    • adjustable measuring time to 99'59'’
    • metered T1, T2 and T3 test times for measuring one or two absorption coefficients from the range of 1…600 s
    • polarization index (PI), absorption coefficients Ab1, Ab2 and dielectric absorption ratio (DAR) measurement
    • indication of actual test voltage during measurement
    • 1.2 mA, 3 mA and 5 mA test current
    • insulation resistance measurement using two- or three-wire method
    • measurements with test leads up to 20 m
    • protection against measuring live objects
    • automatic measurement of multiple core cables with the additional AutoISO-5000 adapter
    • measurement of capacitance during the measurement of RISO
    • measurement of temperature (with additional probe - WASONT1)
    • step voltage insulation resistance measurement (SV)
    • Dielectric Discharge calculation (DD)
    • location of damage (burnout)

    https://www.youtube.com/watch?v=DyOH7K4Yoqg

     

  • MIC-2501 Insulation Resistance Tester/Meter

    MIC-2501 Insulation Resistance Tester/Meter

    Call for price

    MIC-2501 Insulation Resistance Tester/Meter - Overview

    A very handy tool for measuring Insulation resistance with up to 2500V.  It can measure up to 1TOhms in accordance with IEC61557-2. Comes with a convenient carry case which has straps to free up your hands during operations.

    MIC-2501 Insulation Resistance Tester/Meter - Features

    • Selectable voltage in the 100…2500 V range with 100 V step
    • Continuous indication of insulation resistance or leakage current
    • Automatic discharge of capacitance of tested object after the insulation resistance measurement
    • Acoustic signalling of five-second periods to facilitate obtaining time characteristics
    • Measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s
    • Indication of actual test voltage during the measurement
    • Protection against measuring live objects
    • Two and three-lead measurement methods
    • Continuity measurement of protective and equipotential conductors according to EN 61557-4
    • Leakage current measurement
    • Alternating and direct voltages in the 0...750 V range
    • Built-in rechargeable battery pack
    • The instruments meet the requirements of the EN 61557 standard
    • Charge from car lighter (12 V) socket (additional accessories)

    https://www.youtube.com/watch?v=ZKKcoVvN-B8