Tag: Dryers

Dryers

  • Harsh Environment Temperature and Humidity Transmitter THM50X

    Harsh Environment Temperature and Humidity Transmitter | THM50X

    Harsh Environment Temperature and Humidity Transmitter  - Overview

    This transmitter combines rugged durability with measurement precision. It contains a Class A Pt100 with a capacitive humidity sensor. The measuring range for the wall mount is -40°C ... +80°C, and the remote type: -40°C ... +150°C, with an accuracy of ±0.1°C / ±1%RH. Applications include laboratories, HVAC, manufacturing, and industrial process monitoring.

    Harsh Environment Temperature and Humidity Transmitter  - Features

    • Aluminium alloy casing for harsh environments
    • Direct key operation for temperature/humidity adjustment, RS-485 settings, and unit switching
    • High-accuracy temp & humidity measurement
    • Fast response and quick recovery after condensation
    • RS-485 communication for configuring measurement units, ranges, output type, and station address
    • DATA LOG function records up to 65,535 entries for analysis
    • Measures extremely low humidity, down to 0.1% RH
    • Multiple physical measurement units switchable: %RH, °C, mbar, g/kg, g/m³, kJ/kg, AH%

     

  • Industrial Dew Point Transmitter THS88ECO

    Industrial Dew Point Transmitter | THS88ECO

    Industrial Dew Point Transmitter  - Overview

    This dew point transmitter is used to monitor gas dryness and ensure system efficiency and safety. The standardised installation combines flexibility and efficiency, making maintenance easier and data more reliable. It has high accuracy and low error: ±2.5 dp°C accuracy, maintaining minimal deviation under varying dew point conditions. It has a wide measuring range: –80 ... +20 dp°C dew point. This covers ultra-low humidity to standard industrial drying environments. The fast response time, t₉₀ < 20 s, allows it to react quickly to environmental changes. It has a high level of consistency as it is calibrated by the gas-mixing method and verified through cyclic testing (IEC 61298 & ISO 17025 procedures). It is durable and corrosion-resistant thanks to its aluminium alloy housing, SUS304 probe, and SUS316 sintered filter. Applications include compressed air systems, air separation equipment, freezers, adsorption machines, plastic dryers, industrial drying processing, paper, and chemical process monitoring.

    Industrial Dew Point Transmitter  - Features

    • OEM Economic-Type Bulk Products
    • Sensor type: Capacitive humidity sensor & Pt100
    • Output: 4 ... 20 mA / 0 ... 10 V / RS-485
    • Accuracy: ±2.5 dp°C
    • IP rating: IP65 (Probe : IP20)
    • Wide measuring range: -80 ... +20°C dew point
    • Response t90 < 20s
    • Standardised installation: Universal 1/2″ G thread
    • Interference resistance & reliability
    • Durable and corrosion-resistant
    • High consistency
  • Average Flow Thermal Mass Transmitter FDM06-P

    Average Flow Thermal Mass Transmitter | FDM06-P

    Average Flow Thermal Mass Transmitter - Overview

    This Thermal Mass Transmitter stabilises airflow direction and velocity distribution, leading to improved measurement accuracy and consistent sensor output. It uses a multi-point averaging Pitot tube, which samples airflow across multiple points in the duct to determine a representative average velocity. Suitable for Compressed Air System Management, Optimisation of Air Compressors & Pneumatic Equipment Efficiency,  Air Dryer Flow Control,  Process Gas Consumption Monitoring (N2, Ar, CO2, etc.),  Pipeline Leak Detection & Alerts,  HVAC Duct Monitoring,  Smart Manufacturing Energy Management,  Cleanroom Airflow Monitoring,  Biotech & Pharmaceutical Gas Supply Stability Monitoring,  Food Processing Gas Filling & Packaging Monitoring.

    Average Flow Thermal Mass Transmitter - Features

    • Sensor type: Hot-wire sensor
    • High Sensitivity
    • Low Pressure Loss
    • Detects Minute Airflow Changes
    • No Compensation Needed, Direct Flow Output
    • Sizes 2″~12″, Easy Installation
    • ±1.5% F.S. Accuracy, 16 bar Pressure Resistance
    • Analogue, Relay, RS-485 Outputs
    • Suitable for various types of gases (N2, Ar, CO2, etc.)
    • Turndown ratio: 100: 1
    • Output : 4 ... 20 mA / 0 ... 10 V / Relay / RS-485
    • Accuracy : 0.5 ... 60 m/s:±(1.5% of mv + 0.8 m/s)
    • IP rating: IP65
  • Venturi Thermal Mass Flow Meter FDM06-I

    Venturi Thermal Mass Flow Meter | FDM06-I

    Venturi Thermal Mass Flow Meter - Overview

    This Thermal Mass Flow Meter features a Venturi structure, which guides airflow through a contraction-expansion zone to ensure steady and uniform flow across the sensing element. This flow conditioning structure helps to stabilise the airflow direction and velocity distribution, leading to improved measurement accuracy and consistent sensor output. Suitable for Compressed Air Systems, Pneumatic Systems,  Dryers, Air Consumption Monitoring, and Pipeline Leak Monitoring.

    Venturi Thermal Mass Flow Meter  - Features

    • Precise Measurement: unique Venturi tube structure
    • 2″ LCD Screen: Easily configurable with buttons
    • Shows instant and cumulative measurements
    • Screen rotates 90 degrees for easy viewing
    • Multiple Pipe Diameters Available : (DN15 / DN25 / DN40 / DN50 / DN80 / DN100)
    • Accuracy: ±1.5% F.S., pipeline withstand pressure of 16 bar
    • Multiple Outputs: Analogue output / Relay / RS-485

     

  • Gas Combustion Analyser | Enerac 700

    Gas Combustion Analyser - Overview

    This portable combustion analyser is perfect for gathering extremely accurate and reliable data for internal needs as well as for the necessary emissions reporting requirements. All Model 700 Base Units come complete and measure O2 (Oxygen) and CO (Carbon Monoxide). The Enerac Model 700 is hand-held, weighs 2.8kg and is easy to operate with no technical expertise needed. The Model 700 units are rugged, made with a metal case which can withstand years of use. Affordable, accurate, reliable, and sophisticated. Enerac custom builds all units and can engineer sensor ranges and options to customer requirements for their respective applications. The back of the unit has easy thumb screws to remove the backplate to easily replace sensors. It can also be field calibrated without having to send it back to the factory. It is fully upgradeable as one can order new sensors and options to the same unit over time.

    The Model 700 also has a standard sample conditioning system (thermoelectric condenser also called a Peltier cooler) necessary for the proper detection and measurement of both NO2 and/or SO2 gases. The Model 700 also has proper control over the NO sensor's tendency to drift over time with increasing ambient temperatures. The Enerac Model 700’s NO SEM sensor incorporates a proprietary temperature control system designed to automatically hold the nominal filter and sensor temperatures at <30 degrees C. This ultimately prevents rising measurement data drift and maintains the actual lower readings of the NO (NOx). This in turn prevents one from overstating one’s NO (NOx) emissions. The Enerac Model 700 combines high-quality tubing (Viton hose with its specific dimensions and flow rate) along with an accurate and reliable conditioning system (Peltier cooler) with the additional benefits of the extremely accurate SEM sensors.

    The Enerac Model 700 comes with 500 internal storage buffers for storing collected data during a testing event. With Enerac’s free Enercom software, one can use it during the testing event or download the stored data at a later date. There is a RS 232 port, USB port and Bluetooth for communicating with your computer.

    It is one of the most accurate and reliable portable combustion emission analysers in the world.

    Gas Combustion Analyser- Features

    • Rugged durable design
    • O2 (Oxygen) and CO (Carbon Monoxide) Measurment
    • SEM sensors are available in Dual Ranges
    • Easy access for replacing sensors in the field
    • Portable hand-held, weighs only 2.8kg
    • Proprietary temperature control system for reliable NO
    • True NOx Readings at Multiple Levels
    • Built-In Printer
    • Extremely accurate and reliable data for emissions reporting requirements
    • Two-Year Warranty