Venturi Thermal Mass Flow Meter | FDM06-I

Venturi Thermal Mass Flow Meter | FDM06-I

Venturi Thermal Mass Flow Meter – Overview

This Thermal Mass Flow Meter features a Venturi structure, which guides airflow through a contraction-expansion zone to ensure steady and uniform flow across the sensing element. This flow conditioning structure helps to stabilise the airflow direction and velocity distribution, leading to improved measurement accuracy and consistent sensor output. Suitable for Compressed Air Systems, Pneumatic Systems,  Dryers, Air Consumption Monitoring, and Pipeline Leak Monitoring.

Venturi Thermal Mass Flow Meter  – Features

  • Precise Measurement: unique Venturi tube structure
  • 2″ LCD Screen: Easily configurable with buttons
  • Shows instant and cumulative measurements
  • Screen rotates 90 degrees for easy viewing
  • Multiple Pipe Diameters Available : (DN15 / DN25 / DN40 / DN50 / DN80 / DN100)
  • Accuracy: ±1.5% F.S., pipeline withstand pressure of 16 bar
  • Multiple Outputs: Analogue output / Relay / RS-485

 

Description

Venturi Thermal Mass Flow Meter | FDM06-I

Input
Sensor type
Hot-wire sensor
Turndown ratio 100: 1
Measuring range*
DN15 : 76 Nm³/h
DN25 : 220 Nm³/h
DN40 : 600 Nm³/h
DN50 : 1000 Nm³/h
DN80 : 2500 Nm³/h
DN100 : 4000 Nm³/h
*The measurement range is defined at the standard condition(1013 mbar, 20°C).
Output
Output signal
4 … 20 mA / 0 … 10 V / RS-485
Signal connection M12 3-wire
Warm-up time 60 sec
Response time t90≦6 sec
Load resistance
Current output: ≦500 Ω
Voltage output: ≧10 KΩ
Communication
Communication methods & protocol
RS-485 Modbus RTU
RS-485 baud rate
9600、19200、38400、57600、115200 bps
Accuracy ( at 25°C )
Accuracy ±1.5% F.S.
Temp. influence 0.2% / °C
Repeatability 0.50%
Environmental
Medium
Non-corrosive gas
Operating Temp. & Humid.
0 … 50°C / 20 … 90%RH(Non-condensing)
Storage Temp. -20 … +60°C
Operating pressure 16 bar
Electrical
Power supply
DC 24 V ±10%
Current consumption
24 V: 110 mA
Relay capacity
Max current: 6 A
Max voltage: DC 24 V (DC 36 V Max)
Electrical connection
M12 8P connector
Installation
Pipe connection G thread
Pipe size DN15 ( 1/2″ )
DN25 ( 1″ )
DN40 ( 1-1/2″ )
DN50 ( 2″)
DN80 ( 3″)
DN100 ( 4″)
Display
Display readout
0 … 99999999 (Cumulative flow: 8-digit)
0 … 99999 (Instantaneous flow: 5-digit)
Decimal point Button
Sampling time 1 cycle/sec
Flow unit
mL、L、m³、gal、ft³、inch³、UK gal
Time unit /min、/hr
Response time adjustment range
0.5 … 300 sec
Certification
Certification CE
Protection
IP rating IP65
Electrical protection
■ Reverse polarity ■ Over-voltage
Material
Pipe
Aluminum alloy
Housing
Aluminum alloy
Weight
DN15 ( 1/2″ ): 0.9 Kg
DN25 ( 1″ ): 0.8 Kg
DN40 ( 1-1/2″ ): 1.1 Kg
DN50 ( 2″): 1.3 Kg
DN80 ( 3″ ): 5.4 Kg
DN100 ( 4″): 9.4 Kg

Note: Design and specifications are subject to change without notice.
Note: If the product has RS-485 function, to avoid damaging product, please make sure the product and the device which connect with RS-485 are on common ground.