High-end Meteorological Humidity Probe | HC2A-S3A

High-end Meteorological Humidity Probe | HC2A-S3A

R14,099.00 ex vat

High-end Meteorological Humidity Probe- Overview

The HC2A-S3A probe has a wire-mesh filter with 10 µm filter pore size suitable for meteorological applications. It measures relative humidity and temperature and calculates the dew/frost point and is designed for the use in Rotronic meteorological applications.

High-end Meteorological Humidity Probe – Features

  • For use in meteorological applications
  • New humidity sensor HYGROMER HM1-SK
  • Outstanding accuracy, repeatability and long-term stability
  • Accuracy: ±0.8 %rh, ±0.1 K, at 23 °C (10…30 °C)
  • Range of application: -50…80 °C / 0…100 %rh
  • Available with interchangeable sensor
  • Calculates the dew/frost point
  • Saves adjustment data so that probes can be interchanged without re-adjusting (Hot-swappable)
  • Compatible with Rotronic devices HF5, HF8 and HP32
  • Digital interface (UART)
  • Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh

Datasheet

Description

High-end Meteorological Humidity Probe | HC2A-S3A

Probe type High-End Meteorological Probe
Humidity sensor Hygromer HM1-SK
Temperature sensor PT100 1/3 DIN Class B
Long-term stability <1 %rh / year with clean air or similar (See also pollutant table in the catalogue)
Accuracy w. adjustment profile “standard” ±0.8 %RH / ±0.1 K, at 10…30 °C
Adjustment at 23 °C and 10, 35, 80 and 90 %RH
Reproducibility Airchip <0.02 %rh / 0.01 K
Response time t 63 <15 sec.
Power consumption 3.3…5 VDC, Calibration @ 3.3 VDC / ~4.5 mA
Dimensions Ø15 x 108 mm
Operating range -50…80 °C / 0…100 %rh
Allowed wind speed Max. 50 m/s, with wire-mesh filter
Exploitation software ROTRONIC HW5
Psychrometric calculations Dew or frost point
Analogue outputs scaleable by the user Yes
Software Update With internet and HW5 software
User information from Software HW5 (device manager)
Type of output signals 2 x 0…1 VDC
Digital output signal (standard) UART
Service Interface UART
FDA/GAMP compatibility FDA 21 CFR Part 11 and GAMP compatible
Probe adjustment by software 1 Point & multipoint %rh & °C
Device Protection by password Yes
Analog output signal (standard) 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C
Communication interfaces UART
Reverse voltage protection Mechanically in the connector
Max. cable length Up to 5 m with passive cable. Up to 100 m with active cable.
Probe protection Polycarbonate plastic cage, white
Enclosure material Polycarbonate
Weight 17 g
Data Processing via HW5 with interface cables
Filter type Wire mesh filter, 10 μm

Calibration certificates are issued during the production process. New calibration certificates are available upon request at an additional cost.

High-end Meteorological Humidity Probe | HC2A-S3A

Brand

Rotronic

Reviews

There are no reviews yet.

Be the first to review “High-end Meteorological Humidity Probe | HC2A-S3A”