Handheld Circuit Breaker Analyser | CAT Series

Handheld Circuit Breaker Analyser | CAT Series

Handheld Circuit Breaker Analyser  – Overview

The Handheld Circuit Breaker Analyser is ideal for use when it’s not practical to use a conventional robust circuit breaker. It is specially designed for testing circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium, and high-voltage substations or in industrial environments. It consists of two models,  the CAT-P and CAT-H. Both have a large (5,7 in) coloured touch-screen display. Test results are visible in dark places as well as in bright sunlight. The Li-Ion battery can last up to 8 hours of testing without recharging. It records: main contacts operating times, contact synchronisation, sequence time, a resistance of pre-insertion resistors, open and close coil currents, main contacts bounce time, auxiliary contact time, and DC Voltage. Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering a signal from current clamps connected to the circuit breaker coil. CAT-H is capable of performing coil control, while this feature is optional for the CAT-P. In contrast to CAT-H, the CAT-P instrument can execute the “First Trip” test. Both instruments display numerical and graphical results. A user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects. Test results can be downloaded to a PC via Bluetooth interface for more detailed analysis using DV-Win software.

  • Compact and ergonomic design – only 1,6 kg (3.5 lbs)
  • Simple and easy to operate
  • Battery operation for up to 8 hours
  • Timing and coil current measurement
  • Coil control (built-in) for OPEN and CLOSE coil
  • Graphical results for quick interpretation
  • Touch screen colour display 145 mm (5.7 in)
  • On-site analysis of test results (overlay up to 4 records in graphical form)

Description

Handheld Circuit Breaker Analyser | CAT Series

Main contact inputs
Number of contact inputs: 3 (3 x 1), 1 per phase
Each channel detects Main contacts Closed ≤ 10 Ω
Resistor contacts range 10 Ω to 5 kΩ
Open ≥ 5 kΩ
Open circuit voltage: 20 V DC ±20%
Short circuit current 50 mA
Time measurement Time measurement resolution:
0,05 ms to 10 ms depending on test duration (sampling rate up to 20 kHz)
Time accuracy:
0,05% of the reading ± resolution
Breaker operation Close (C)
Open (O)
Close-Trip (C-O)
Trip-Close (O-C)
Trip-Close-Trip (O-C-O)
DC Current Clamps Nominal current: 300 ARMS or 450 A DCPK
Measuring ranges: 30/300 A
Frequency range: DC to 20 kHz (-3 dB)
DC Voltage Measurement Range: ±300 V
Typical accuracy:
±0,5% RDG ±0,5% FS
Guaranteed accuracy:
±1% RDG ±1% FS
Coil driver Number of channels:
2 (Trip and Close coil)
Driver characteristics:
± 300 V DC / AC peak, ±35 A DC to 5 kHz
Electronic drivers provide superior timing control
Overcurrent and overvoltage protection
Coil supply input:
± 300 V DC / AC peak, ±35 A DC to 5 kHz
Current measurement
Current measurement for Trip and Close coil, 2 channels, Hall-Effect sensor
Range
±35 A DC to 5 kHz
Accuracy
± (0,5 % rdg + 0,1 % FS)
Graphic presentation: currents waveform is displayed with a resolution of 0,1 ms
Handset and inline power supply 12 V DC, 5 A
Input:
90 – 264 V AC, 50/60 Hz
Internal battery supply
2 x 3,7 V, 2900 mAh rechargeable Li-ion battery
8 hours under normal usage
Display Touch screen colour display 145 mm (5.7 in)
Internal Memory
Store over 30,000 test results (including numerical and graphical results)
Applicable standards Safety:
Low Voltage Directive: Directive 2014/35/EU (CE conform)
Applicable standards, for a class I instrument, pollution degree 2,
Installation category II: IEC EN 61010-1
Electromagnetic Compatibility:
Directive 2014/30/EU (CE conform)
Applicable standard: EN 61326-1
CAN/CSA-C22.2 No. 61010-1
Environmental conditions Operating temperature:
-10 ºC to + 55 ºC / 14 ºF to +131 ºF
Storage & transportation:
-40 ºC to + 70ºC / -40 ºF to +158 ºF
Humidity
0 % – 95 % relative humidity, non-condensing
Dimensions and weight Dimensions (L x W x H):
310 x 170 x 58 mm / 12.21 x 6.69 x 2.28 in
Weight: 1,6 kg / 3.5 lbs
Encapsulation class / Ingress protections IP40
Warranty
3 years + additional 1 (one) year upon registration on DV Power official website (www.dv-power.com)

Handheld Circuit Breaker Analyser | CAT Series

Brand

DV Power

IBEKO Power AB, with headquarters in Stockholm (Sweden) and best known through the brand ”DV Power”, has developed radically light and ingenious test solutions for transformers, circuit breakers, and batteries. Founded by a group of engineers with deep knowledge and experience in the power electronics technology area. Sold worldwide – in over 100 countries. Their success is solely based on extensive research, development, and fast commercial application.

Reviews

There are no reviews yet.

Be the first to review “Handheld Circuit Breaker Analyser | CAT Series”