Category: Temperature Probes

Temperature Probes

  • Digital Humidity and Temperature Probe PC62/62V

    Humidity and Temperature Probes | PC33 and PC52

    Price range: R5,130.00 through R8,923.00 ex vat

    Humidity and Temperature Probes - Overview

    These cost-effective analogue probes are designed for HVAC and controlled environment applications. They also have great stability.

    Humidity and Temperature Probes - Features

    • Accuracy used in precision manufacturing applications
    • Built with interchangeable Hygrosmart module
    • Different probe types; analog or digital
    • Available in molded Polymer or stainless steel
    • Application range: 0…100 %rh, -20…80 °C
    • Accuracy PC52: ±2 %rh (10...90 %rh), ±0.2 K @ 23 °C
    • Accuracy PC33: ±3 %rh (30...80 %rh), ±0.3 K @ 23 °C
    • Stability: ±1 %rh/year
  • Negative Temperature Coefficient Sensors RMS T10-0006

    Negative Temperature Coefficient Sensors | RMS T10-0006

    NTC Temperature Sensors - Overview

    The T10 temperature sensors are Negative Temperature Coefficient thermistors. This means the resistance of the NTC decreases with increasing temperature. The temperature sensors are compatible with the RMS-MLOG-T10-868/915 data loggers.  Applications include liquid nitrogen tanks, cryogenic freezers, refrigerators, cold rooms, water baths, incubators, ovens and autoclaves. Certain probes are also designed for specific applications for monitoring legionella within water pipes and monitoring room temperature. It is crucial when setting up your logger with the T10 temperature probe to configure the logger accordingly, as the characteristic curve of each NTC is stored in the firmware.

    NTC Temperature Sensors - Features

    • NTC sensor
    • No influence from the lead
    • High-temperature sensitivity
    • Sensor application range: -80...150⁰C
    • High accuracy
  • RMS Temperature Sensor RMS T30-0006

    RMS Temperature Sensor | RMS T30-0006

    RMS Temperature Sensor - Overview

    The T30-006 temperature sensor is a resistance thermometer (Pt100 = positive measurement resistance), meaning that the resistance increases with increasing temperature. The sensors are compatible with the Rotronic RMSLOG- T30-L, RMS-LOG-T30-868 and RMS-LOG-T30-915 data loggers. Sensor measurement range -200...+600 °C. Applications include dry ice, freezers and water baths.

    RMS Temperature Sensor  - Features

    • Sensor measurement range -200...+600 °C
    • PT100 1/3 DIN B
    • No influence from the lead
    • High measurement accuracy

    Datasheet

  • 7 Parameter Weather Sensor | u[sonic]WS7

    7 Parameter Weather Sensor - Overview

    The usonicWS is a compact and system-capable weather sensor.  Wind direction and speed are measured by ultrasound sensors. Wind parameters, global radiation, air temperature, humidity and pressure values are also measured. The dew point is calculated. The lamella shelter of the humidity and temperature sensor protects the sensor from the effects of the climate and ensures improved and more accurate measurements. A wide variety of interfaces and protocols are available. Suitable for a wide variety of applications.

    Applications include:

    • professional meteorological applications
    • on- and off-shore wind turbines
    • building automation and environmental engineering
    • traffic and industrial meteorology
    • wind warning and event engineering
    • photovoltaic large-scale plants
    • alpine applications

    7 Parameter Weather Sensor - Features

    • no moving measuring elements
    • 7 weather parameters: wind direction and speed, air temperature, rel. humidity, barometric pressure, global radiation, dew point
    • intelligent heating depending on wind speed and wind direction
    • lamella shelter for accurate mea­surements of the temperature-humidity sensor
    • easy installation
    • easy maintenance
  • Humidity and Temperature Probes for Harsh Conditions | PCMini52

    Humidity and Temperature Probes for Harsh Conditions - Overview

    The Rotronic PCMini52 is used for excellent accuracy and performance in harsh conditions. These miniature rh and temperature probes are available with digital or analogue outputs. It is suitable for environmental control applications.

    Humidity and Temperature Probes for Harsh Conditions - Features

    • Application range: 0…100 %rh, -20…80 °C
    • Accuracy: <±2 %rh (10...90 %rh), ±0.2 K @ 23 °C
    • Stability: ±1 %rh/year
    • Output: RS485 Modbus RTU
    • Molded polymer or stainless steel
    • Highly accurate measurements
    • Built-in interchangeable Hygrosmart module
    • Analog or digital probes

     

  • Thermocouple Thermal Resistance Temperature Sensors RTD/TC

    Thermocouple Thermal Resistance Temperature Sensors | RTD/TC

    Thermocouple Thermal Resistance Temperature Sensors - Overview

    Thermocouple (T/C) Thermocouple sensors are made from two wires. Each wire is a different type of metal. These are then welded together to form a measuring/hot junction. This junction and the wires are usually enclosed in a protective metal tube which is inserted into the medium where the temperature is to be measured. The opposite end of the two wires is also joined, and that point is known as the cold junction. As the temperature at the measuring junction changes, thermal current movement occurs between the hot and cold junctions, generating an electron flow. The measurement of this electron flow can then be referenced to a formula, which converts the reading to °C or °F.  The thermal current motion of a thermocouple relates directly to the types of wires used.

    RTD platinum resistance: is a sensor whose resistance changes as its temperature changes. The resistance increases as the temperature of the sensor increases. The resistance vs temperature correlation is well established and is repeatable over time. The temperature is measured with the resistance of pure metal wires, and the resistance increases at a fixed ratio as the temperature increases. Resistance thermometers are made of platinum, nickel, or copper - with platinum being more commonly used because of its stability and reproducibility.

    Thermocouple thermal resistance temperature sensor specifications and sizes can be customized according to different needs.

    Thermocouple Thermal Resistance Temperature Sensors

     

     

  • External Temperature Probe AC1215

    External Temperature Probe | AC1215

     External Temperature Probe

    The External Temperature Probe | AC1215 is to be used with the CL11 Data Logger for indoor air quality.