High Accuracy Oxygen Analyser | Rapidox 1100-OPT-MAX

High Accuracy Oxygen Analyser | Rapidox 1100-OPT-MAX

High Accuracy Oxygen Analyser – Overview

This analyser is ideal for challenging applications such as measuring ppm levels of oxygen in hydrogen, helium and flammable gases, as well as high levels of oxygen in concentrators, incubators and glove boxes. The high and low-range oxygen sensors switch over automatically using a hysteresis function to optimise readings, with an adjustable switching point. The optical oxygen sensors are virtually drift-free and are factory-calibrated for life, making their lifetime cost of ownership more economical. These sensors are suitable for demanding high-oxygen applications where VOCs, flammable gases, CO, H₂ or He are present in the gas sample.

The optical oxygen sensor technology is based on luminescence quenching of a sensor dye. The dye is excited with red light, and the properties of the resulting luminescence are measured in the near infrared. The presence of molecular oxygen in the gas quenches the luminescence, changing its intensity and producing a calibrated oxygen measurement. This principle is very robust, shows virtually no interference from other gases and has a very low drift. It does not deplete over time, unlike galvanic oxygen sensors with their limited shelf life, as the optics and electronics are hermetically sealed from the measured gas. For typical indoor conditions, a 5–10 year operating life is expected.

High Accuracy Oxygen Analyser  – Features

  • Long life
  • Fast response
  • High-accuracy measurement from 0.1 ppm to 100% oxygen
  • Low drift
  • Factory calibrated
  • Digital output of oxygen partial pressure
  • Temperature compensation
  • Low power consumption
  • Lead-free, ROHS-compliant

Description

High Accuracy Oxygen Analyser | Rapidox 1100-OPT-MAX

Type Measurement
Max Gas Pressure 500-1500 mbar absolute
Max Gas Temperature 50°C
O2 Sensor Range High Range Sensor 0.1-100%; Low Range Sensor 0-2500ppm
O2 Sensor Accuracy / Response High range: ±1% of full scale; Low range: 1ppm ±0.15ppm; 100ppm ±0.8ppm; >200ppm ±1.5ppm; High Range: < 2 secs for a 90% response; Low range: < 10 secs for a 90% response
O2 Sensor Life Expectancy Between 5 & 10 years, depending on sample frequency
Warm-up Time 3-5 minutes as standard
Voltage 90-260VAC, 50/60Hz
Voltage Outputs 0-10V, user programmable
Current Outputs 4-20mA linear, user programmable
Digital Outputs RS232 (RS485 option available): data streamed on demand/Modbus RTU/Ethernet
Calibration Requires 2 user-selectable gas compositions. Normally zero and span
Sample Connections 4mm ID / 6mm OD nipple type Rectus or Swagelock Front or rear positioning
Display 20 x 4 character OLED
Analyser Dimensions Bench: 150mm(H) x 247mm(W) x 250mm(D) Panel: 300 x 4U (177mm(H) x 300mm(W)) Multiplex: 150mm(H) x 263mm(W) x 250mm(D)
Weight 3.5kg (4kg with bezel)
Pump Option Mains type diaphragm pump. Variable speed 0-1.2 litres per min
Ejector Option Vacuum ejector fitted, running off 2 bar inlet pressure
Alarm Relay circuits. Fully user programmable

High Accuracy Oxygen Analyser | Rapidox 1100-OPT-MAX

Brand

Cambridge Sensotec

advancing excellence in gas analysis
Cambridge sensotec logo

Reviews

There are no reviews yet.

Be the first to review “High Accuracy Oxygen Analyser | Rapidox 1100-OPT-MAX”