Category: Flow Meters

Flow Meters

  • Thermal Mass Diff. Pressure Signal Processor FDM06-X

    Thermal Mass Diff. Pressure Signal Processor | FDM06-X

    Thermal Mass Diff. Pressure Signal Processor  - Overview

    This high-accuracy thermal-mass differential-pressure sensor includes K-factor correction. The real-time display and versatile outputs make this the ideal tool. It is compatible with multiple throttling devices such as Pitot Tubes, Averaging Flow Tubes, Annubar Tubes, Venturi Tubes, Orifice Plates and V-Cones. It is a hot-wire sensor with a turndown ratio of 100:1 . Its Outputs include 4 ... 20 mA, 0 ... 10 V, Relay, and RS-485. It is accurate at 60 m/s: ±(1.5% F.S.) and has an IP rating of IP65.

    Thermal Mass Diff. Pressure Signal Processor  - Features

    • Thermal mass differential pressure principle
    • High accuracy ±1.5% F.S.
    • No need for temperature or pressure compensation
    • Turndown ratio 100:1 with high sensitivity design
    • On-site K-factor correction
    • Real-time display & system integration
    • Versatile outputs: Analogue, Relay, RS-485
    • Easy installation
    • High compatibility to wide range of differential pressure elements
  • Clamp Thermal Mass Flow Meter RWMF

    Clamp Thermal Mass Flow Meter | RWMF Clamp

    Clamp Thermal Mass Flow Meter - Overview

    This one-of-a-kind mass flow meter is popular in industrial applications because of its design and build. It has no moving parts, a nearly unobstructed flow path and requires no temperature or pressure corrections. It is not affected by vibration on the measurement accuracy. It has good seismic performance and high measurement reliability. It also retains accuracy over a wide range of flow rates. Straight pipe runs can be reduced by using dual-plate flow conditioning elements. Installation and use are easy with minimal pipe intrusions. Mass flow meter sizes range from DN15~DN100mm. Its sensitivity is suitable for low flow rate measurement.  Applications include single or fixed gas flow measurements. It measures gas with flow velocity from 100Nm/s to 0.1Nm/s. The flow meter can also be used for gas leak detection.  It supports multiple communication methods, such as RS485 and MODBUS protocol for factory automation and integration.

    Clamp Thermal Mass Flow Meter  - Features

    • Measuring Medium: Various of Gas (Except acetylene)
    • Pipe Size: DN15-DN2000mm
    • Velocity: 0.1-100Nm/s
    • Accuracy: +/-1~2.5%
    • Working Temperature: Sensor:-40~+220 degC
    • Transmitter:-20~+45 degC
  • Compressed Air VA Flow Meter DS1173

    Compressed Air VA Flow Meter | DS1173

    Compressed Air VA Flow Meter - Overview

    These variable area flowmeters are calibrated for direct reading of compressed air at 7 bar and 20°C. They have metal bodies which operate using a spring loaded orifice moving over a tapered cone, to achieve a variable area meter. Flow is indicated by a magnetic follower ring under a scale on an external glass tube.

    Compressed Air VA Flow Meter - Features

    • Brass, Stainless Steel or Aluminium models
    • Calibrated for direct reading of compressed air at 7 bar and 20°C
    • Works in any orientation
    • Available in 5 sizes
    • Pressures up to 41 bar (600 psi)
  • Explosion Proof Flow Switch DS1432

    Explosion Proof Flow Switch | DS1432

    Explosion Proof Flow Switch - Overview

    This paddle-operated flow switch is suitable for ½" to 2" pipelines. Magnetic coupling between the spring-loaded vane and the microswitch gives a glandless construction. Applications include gases or liquids up to 2,000 psi. Models are available with Stainless Steel or Brass process parts.

    Explosion Proof Flow Switch - Features

    • Suitable for gases and liquids up to 2,000 psi
    • Leak-proof lower body machined from bar stock
    • Weatherproof
    • Low flow model offers field adjustable set point
    • Easy installation
    • ATEX approved

     

     

  • Explosive Environments Mass Flow Controllers IS-Max

    Explosive Environments Mass Flow Controllers | IS-Max

    Explosive Environments Mass Flow Controllers - Overview

    The IS-Max can meter flow while controlling pressure to reduce the system complexity of GCs. The IS-Max is unmatched in hazardous applications. It saves space and reduces maintenance costs with a Zone 0-certified, compact, fully integrated device. No purge cabinet is needed. It improves efficiency with repeatable flow and pressure. It is unaffected by fluctuating process conditions compared to rotameters. It allows 24/7, real-time data reporting in hazardous locations. It comes with a lifetime warranty and free technical support.  The front panel displays live measurements and makes it easy to make adjustments in the field.  It allows consistent and accurate sample batching that can be configured on-site. It comes with ATEX/IECEx certifications to operate in explosive environments. Applications include refineries and petrochemical plants.

    Explosive Environments Mass Flow Controllers - Features

    • Intrinsically safe
    • Minimal maintenance required
    • Customisable monitoring and control
    • Easy to use and versatile
    • Accuracy of flow from ±(0.4% of reading and 0.2% of full scale) to ±(0.8% of reading and 0.2% of full scale)
    • 98-129 field-selectable gas calibrations
    • The first intrinsically safe instrument for flow control—or controlling pressure, while metering flow
    • Easy-to-read display verifies your process instantaneously
    • Digital MODBUS or ASCII, or analog communications
  • Flange Thermal Mass Flow Meter RWMF

    Flange Thermal Mass Flow Meter | RWMF

    Flange Thermal Mass Flow Meter - Overview

    The Flange Thermal Mass Flow Meter is popular in industrial applications because of its design and build. It features no moving parts, a nearly unobstructed flow path, requires no temperature or pressure corrections and retains accuracy over a wide range of flow rates. Straight pipe runs can be reduced by using dual-plate flow conditioning elements. Installation is simple, with minimal pipe intrusions and it is easy to use. Suitable for use on all kinds of single or mixed gas flow measurements. It can measure gas with a flow velocity of 100Nm/s to 0.1Nm/s. It can be used for gas leak detection. It supports multiple communication methods including RS485 communication and MODBUS protocol. Applications include dry gas such as air, natural gas, LPG gas, and biogas.

    Flange Thermal Mass Flow Meter  - Features

    • Measuring Medium: Various of Gas (Except acetylene)
    • Pipe Size: (Insert connection) DN50-DN2000mm, In-line connection (DN10-DN2000mm)
    • Velocity: 0.1-100Nm/s
    • Accuracy: +/-1~2.5%
    • Working Temperature: Sensor:-40~+220 degC Transmitter:-20~+45 degC
  • Gapmeter Type SGUV Platon DS1160

    Gapmeter Type SGUV | Platon DS1160

    Gapmeter Type SGUV - Overview

    The type SGUV and type SGUL are direct reading Flowmeters for clean liquids and gases in pipe sizes larger than 30mm. They provide a robust and cost effective method of flow measurement. The indicator housing can be mounted locally to the pipe or remotely by the use of flexible impulse tubing. The instrument is a combination of two measuring principles. It is essentially a pressure differential device consisting primarily of an accurately machined orifice plate located in the main pipework. This produces a pressure drop proportional to the square of the flow rate. A secondary orifice restrictor located in the by-pass flowmeter is accurately calibrated to produce a by-pass flow that can be measured by the glass VA type flowmeter, scaled in terms of the main pipe flow. The metering elements are manufactured to a high standard of interchangeability with boldly marked indicating scales and dynamically balanced floats.

    Gapmeter Type SGUV - Features

    • Easy of installation
    • Available for various flanges
    • Instantaneous reading
    • Compact and rugged construction
    • Optional flow alarm
    • Maintenance possible under flow conditions
    • Interchangeable components provide low cost unit
    • Only one moving part
    • Calibration for wide range of gases and liquids
  • Gas Roots Turbine Flow Meter QTLL

    Gas Roots Turbine Flow Meter | QTLL

    Gas Roots Turbine Flow Meter - Overview

    High accuracy, good repeatability measurement or detection. It has a variety of structural forms and functional configurations to meet user requirements. The dust-proof stainless steel bearings ensure long service life. The intelligent integrated design can detect temperature and pressure, and perform automatic compensation and compression factor correction. Its dual-power micro-power consumption technology supports a battery lifespan of more than 3 years. Compared with the precession vortex flow meter, the gas turbine flow meter has low-pressure loss, low initiating flow and a wider range ratio. This flow meter is widely used in the flow measurement of natural gas, coal-to-gas, inert gas, air and other gases. It is an ideal flow measurement device for domestic and foreign urban gas, oilfield chemical, scientific research and other departments.

    Gas Roots Turbine Flow Meter - Features

    • Nominal Diameter: DN25-DN200mm
    • Nominal Pressure: 1.6Mpa/2.5Mpa/4.0Mpa
    • Low startup flow: 0.05~0.95m3/h
    • Accuracy: 1.5% (Standard), 1.0% (Optional)
    • Repeatability: Better than 0.2%

    https://www.youtube.com/watch?v=PYlQpf4aCnE

     

  • Gas Turbine Flow Meter QTWG Series

    Gas Turbine Flow Meter | QTWG Series

    Gas Turbine Flow Meter - Overview

    The Gas turbine flow meter is a new generation of high-precision and high-reliability gas measuring instruments. It has excellent low and high-pressure metering performance, various signal output modes and low sensitivity to fluid disturbance. The Gas Turbine Flow Meter boasts advanced rectification technology and a dust-proof structure. It includes built-in temperature and pressure sensors which automatically compensate to ensure high accuracy.  This gas turbine flow meter is used with low pressure loss, and low initiating flow and has a wider measurement range than the other flowmeters in this series. The display can rotate 350°, making it easy to read data in different directions. Applications include natural gas, LPG, coal gas etc. Widely used in various industries of gas metering and gas pressure regulating stations such as petroleum, chemical, electric power, industrial boilers, gas transmission and distribution pipeline networks, and urban natural gas metering.

    Gas Turbine Flow Meter - Features

    • Nominal Diameter: DN25-DN400
    • Nominal Pressure: 1.6Mpa/2.5Mpa/4.0Mpa
    • Range Ratio: Max 40:1 (under P=101.325Kpa, T=293.15K)
    • Accuracy: 1.5% (Standard), 1.0% (Optional)
    • Repeatability: Better than 0.2%
  • Glass Tube Variable Area Flowmeters DS3601-100mm

    Glass Tube Variable Area Flowmeters | DS3601-100mm

    Glass Tube Variable Area Flowmeters -  Overview

    This Glass Tube Flowmeter uses a 100mm scale length borosilicate glass tube and a float. As it is based on the variable area (VA) principle, these flowmeters provide clear, simple and reliable operation. They are individually scaled and calibrated according to the customer's requirements. The fluid or gas flows vertically upwards through the tapered glass tube, causing the float to rise to an equilibrium position. The flow rate is measured by reading the top edge of the float against the scaled tube. Suitable for use with gasses or water (eg. cracked ammonia, helium, hydrogen, methane, nitrogen, oxygen, propane).

    Glass Tube Variable Area Flowmeters - Features

    • Instantaneous response
    • Simple and reliable operation
    • Low line pressure loss
    • High resolution
    • Custom scales available on request
  • Horizontal Display Metal Tube Rotameter | QTLZ Table 1: Horizontal Display Metal Tube Rotameter Data Sheet Measuring range Water (20℃)                  16~150000 l/h. Air (0.1013MPa 20℃)       0.5~4000 m3/h.  Range ratio 10:1 (Special type 20:1).  Accuracy class 2.5 (Special type 1.5% or 1.0%).  Working pressure DN15~DN50 PN16 (Special type 2.5MPa). DN80~DN150 PN10 (Special type 1.6MPa). Pressure rating of jacket 1.6MPa.  Medium temperature Normalised type -80℃~+220℃. High-temperature type 300℃. Lined with FEP type ≤85℃.  Ambient temperature -40℃~+120℃ (Remote display without LCD≤85℃). (Remote display with LCD≤70℃).  Dielectric viscosity 1/4” NPT, 3/8” NPT 1/2” NPT≤5mPa.s 3/4” NPT,1” NPT ≤250mPa.s  Output Standard signal: two-wire system 4 ~ 20mA (with HART communication) Standard signal: three-wire system 0 ~ 10mA Alarm signal:1.Two-way relay output 2. One-way or two-approach switches Pulse signal output: 0-1KHz isolated output  Process connection Standard type:24VDC±20% AC type:220VAC(85~265VAC) (optional)  Connection mode Flange Thread Tri-clamp  Levels of protection IP65/IP67.  Ex-mark Intrinsically safe: ExiaIICT3~6.    Exd type: ExdIICT4~6. Table 2: Horizontal Display Metal Tube Rotameter Flow Range Calibre (mm) Work number Flow range Pressure loss kpa Water L/h Air m3/h Water Kpa Air Normal type Anti-corrosion type Normal type Anti-corrosion type Normal type Anti-corrosion type 15 1A 2.5~25 -- 0.07~0.7 6.5 - 7.1 1B 4.0~40 2.5~25 0.11~1.1 6.5 5.5 7.2 1C 6.3~63 4.0~40 0.18~1.8 6.6 5.5 7.3 1D 10~100 6.3~63 0.28~2.8 6.6 5.6 7.5 1E 16~160 10~100 0.48~4.8 6.8 5.6 8.0 1F 25~250 16~160 0.7~7.0 7.0 5.8 10.8 1G 40~400 25~250 1.0~10 8.6 6.1 10.0 1H 63~630 40~400 1.6~16 11.1 7.3 14.0 25 2A 100~1000 63~630 3~30 7.0 5.9 7.7 2B 160~1600 100~1000 4.5~45 8.0 6.0 8.8 2C 250~2500 160~1600 7~70 10.8 6.8 12.0 2D 400~4000 250~2500 11~110 15.8 9.2 19.0 40 4A 500~5000 300~3000 12~120 10.8 8.6 9.8 4B 600~6000 350~3500 16~160 12.6 10.4 16.5 50 5A 630~6300 400~4000 18~180 8.1 6.8 8.6 5B 1000~10000 630~6300 25~250 11.0 9.4 10.4 5C 1600~16000 1000~10000 40~400 17.0 14.5 15.5 80 8A 2500~25000 1600~16000 60~600 8.1 6.9 12.9 8B 4000~40000 2500~25000 80~800 9.5 8.0 18.5 100 10A 6300~63000 4000~40000 100~1000 15.0 8.5 19.2 150 15A 20000~100000 -- 600~3000 19.2 -- 20.3 Table 3: Horizontal Display Metal Tube Rotameter Model Selection QTLZ X X X X X X X X X Indicator Code Local indicator Z LCD indicator with output D Nominal diameter Code DN15 -15 DN20 -20 DN25 -25 DN40 -40 DN50 -50 DN80 -80 DN100 -100 DN150 -150 Structure Code Bottom-top / Left-right (horizontal) H1 Right-left (horizontal) H2 Side-side AA Bottom -side LA Thread connection S Tri-clamp M Body material Code 304SS R4 316LSS R6L Hastelloy C Hc4 Titanium Ti Liner F46(PTFE) F Monel M Indicator type Code Iinear indicator(pointer indication) M7 Nonlinear indicator(LCD Display) M9 Combination function(only for LCD display) Code 24VDC with 4~20mA output S 24VDC with HART communication Z Battery power D Additional function Code Measuring tube with thermal preservation/heat insulation jacket T Measure medium temperature higher than 120.C HT Ex-proof: Code With W Without N Alarm Code One alarm K1 Two alarm K2 None N Horizontal Display Metal Tube Rotameter QTLZ

    Horizontal Display Metal Tube Rotameter | QTLZ

    Horizontal Display Metal Tube Rotameter - Overview

    This Variable Area Rotameter is suitable for single-phase liquids or gas flowing in small/medium pipe diameters. It can be used with corrosive, toxic and explosive mediums. It has good stability and reliability. It has an easy-to-read LCD digital display screen and is easy to install. Applications include the Chemical, Pharmaceutical, Petrochemical, Food, and Metallurgical Industries.

    Horizontal Display Metal Tube Rotameter - Features

    • Horizontal Installation, easy installation and observation
    • Good stability and reliability
    • Suitable for single-phase liquid/gas with small/medium pipe diameter
    • Can be used for corrosive, toxic and explosive mediums
    • Two-wire 4~20mADC signal output
    • Easy-to-read LCD digital display
    • Range ratio: 10:1 (Special type 20:1)
    • Accuracy class: 2.5 (Special type 1.5% or 1.0%)
    • Medium temperature: Normalized type -80℃~+220℃
    • Ambient temperature: -40℃~+120℃(Remote display without LCD≤85℃)
    • Working pressure: DN15~DN50 PN16 (Special type 2.5MPa)

    https://youtu.be/npxWCLED5RE

     

  • In-Line Pitot Tube Platon DS1161

    In-Line Pitot Tube | Platon DS1161

    In-Line Pitot Tube - Overview

    The In-Line Pitot Tube "Flo-bar" is a Stainless Steel pipe section with welded-in pitot probes. It is available for ½" to 2" pipes. They are supplied fitted with ¼" ball valves to provide process isolation. Suitable for liquids and gases.

    In-Line Pitot Tube - Features

    • Flow sensors for liquids or gases
    • ±1% of the actual flow rate
    • Flow averaging
    • Internal isolation ball valve
    • No power supply required
    • Full electron beam welded construction

     

  • Low Pressure Drop Mass Flow Meters Whisper MW Series

    Low Pressure Drop Mass Flow Meters | Whisper MW-Series

    Low Pressure Drop Mass Flow Meters - Overview

    These Mass Flow Meters measure mass and volumetric flow rates where there is little available system pressure. This includes pressure drops as low as 4.8 mbarD. Whisper devices are for processes with little available inlet pressure or a large amount of back pressure. These devices have a larger flow body and uniquely arranged laminar flow elements, resulting in pressure drops up to 10 times lower than standard devices. Whisper instruments utilise much more sensitive pressure sensors to take full advantage of the lower pressure readings.

    Low Pressure Drop Mass Flow Meters - Features

    • Simultaneously measure volumetric flow, mass flow, gas pressure, and gas temperature
    • Field-adjustable engineering units and STP/NTP conditions
    • 98+ preloaded NIST-traceable gas calibrations
    • Define and store 20 custom gas mixtures of up to 5 constituent gases
    • Backlit display and control configuration
    • Integrated touchpad
    • Optional integrated dual flow totalisers and alarms
    • Each instrument is built to meet your specific process needs

    https://www.youtube.com/watch?v=DMSabM9BHlw

     

  • Metal Tube Flowmeters SC250

    Metal Tube Flowmeters | SC250

    Metal Tube Flowmeters - Overview

    This variable area, high-performance measurement flowmeter, is suitable for use in extreme working conditions. Can be used in liquid or gas flow measurement. Applications include water treatment plants, pulp & paper and food industries; pharmaceutical, chemical and petrochemical industries; power plants and nuclear-generating plants; heating and cooling circuits; saturated steam circuits; oven treatments and control of gas burners.

    Metal Tube Flowmeters - Features

    • Metallic tube with a robust construction
    • Indication using magnetic coupling
    • High-performance measurement in extreme working conditions
    • High resistance to corrosion
    • Low-pressure drop
    • Damping mechanism to avoid float bounces in gas and steam applications
  • Metal Tube Purge Flowmeter Platon DS1210

    Metal Tube Purge Flowmeter | Platon DS1210

    Metal Tube Purge Flowmeter - Overview

    Ideal for liquid or gas flow monitoring on small lines in purging, mixing or sampling systems. It uses a stainless steel tapered tube to create a variable area flowmeter. The magnetically coupled pointer shows flow rate on an external scale. Metal Tube Purge Flowmeters are used where the higher integrity offered by a metal flow tube is important, or where conventional glass flow tubes are not allowed in the process. The meters are available with inline (API) or rear-facing (APT) screwed connections. For fine flow rate adjustment, the APV model has an integral multi-turn needle valve. Scales are individually produced to show the actual fluid flow for the process fluids and conditions relevant. The units are suitable for flush mounting in a control panel, using a simple mounting kit. Standard units require no electrical connection.

    Metal Tube Purge Flowmeter - Features

    • For high integrity of high-pressure duty
    • Standard units require no electrical connection
    • Suitable for flush panel mounting
    • Scaled for specific process conditions