| Frequency Response Analyser |
|
| Measurement |
Magnitude, Gain (CH1/CH2, CH2/CH1),Gain (dB), Offset Gain (dB), Phase (º) |
| Frequency Range |
5Hz – 45MHz |
| Gain Accuracy in dB |
0.02dB < 50kHz
0.02dB + 0.05dB / MHz < 5MHz
0.1dB + 0.04dB / MHz < 45MHz |
| Phase Accuracy |
0.05º < 10kHz
0.07º + 0.0009º / kHz < 5MHz
5.05º + 0.0001º / kHz < 45MHz |
| Frequency Source |
Generator |
| Measurement |
Real Time DFT, no missing data |
| Speed |
Up to 100 readings per second |
| Filter |
Selectable from 0.2 seconds |
| Resolution |
5 or 6 digits |
| Input Impedance |
50 Ohm or 1M Ohm High Impedance (Selectable) |
| Dynamic Range |
120dB |
| L C R Meter |
|
| Functions |
L,C,R (AC), Q, Tan Delta, Impedance, Phase – Series or Parallel Circuit |
| Frequency Range |
5Hz to 5MHz |
| Current Shunt |
50R Internal or External |
| Ranges |
Inductance
Capacitance
Resistance |
| Basic Accuracy |
0.5% + 2%/MHz |
| Sweep Capability |
All AC functions |
| Impedance Range |
100m Ohm to 100K ohm |
| True RMS Voltmeter |
|
| Channels |
2 (Ground Referenced) |
| Frequency Range |
5Hz to 5MHz |
| Measurement |
AC, RMS, PEAK, CF, SURGE, dBm |
| Basic Accuracy (AC) |
0.05% range + 0.05% reading + 0.1mV < 1kHz
0.15% range + 0.15% reading + 0.1mV < 10kHz
0.5% range + 0.5% reading + 0.025%/kHz + 0.4mV < 5MHz |
| Signal Generator |
|
| Type |
Direct Digital Synthesis , Single Frequency or Sweep |
| Frequency |
5Hz to 45MHz |
| Waveforms |
Sine, Square, Triangle, Ramp, White Noise |
| Accuracy |
Frequency 5ppm over all temperature range
Amplitude ±5% < 10MHzAmplitude ±10% < 45MHz |
| Impedance |
50 Ohm ± 2% |
| Scaling |
1 x 10^-9 to 1 x 10^9 |
| Output Level |
50mVpk to 10Vpk |
| INPUT RANGES |
|
| Inputs |
2 x 10Vpk |
| Connectors |
Ground referenced BNC |
| Coupling |
AC |
| Max Input |
10Vpk from Earth |
| Input Ranges |
Peak ranging 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V, 10V |
| Scaling |
1 x 10^-9 to 1 x 10^9 |
| Ranging |
Full auto, Up only or Manual |
| Input Impedance |
50 Ohm or 1M Ohm High Impedance Selectable |
| ACCESSORIES AND PORTS |
|
| Instrument Accessories |
|
| Leads |
3 x BNC to BNC (Output, CH1, CH2), RS232, Power |
| Software |
CommView, SFRAComm |
| Documentation |
Calibration Certificate, User Manual |
| Newtons4th SFRA Transformer Connection System |
|
| Bushing Clamps |
2 x Bushing Connection Clamps |
| BNC Cable Reel |
N4L 18m Cable reel (Signal, CH1, CH2) |
| Earth Braid |
2 x 5 meter Earthing Braid |
| Earth Clamps |
2 |
| Spare Earth Braid |
2 x 500mm |
| USB Memory Stick |
2 GB |
| SYSTEM SPECIFICATIONS |
|
| Sweep |
|
| Functions |
FRA, Impedance |
| Steps |
Up to 2000 Steps |
| Window |
From 50ms with no gap between each log |
| Memory |
1 GB Internal or External USB |
| General |
|
| Display |
5.7″ 1/4VGA Colour high brightness backlit |
| Dimensions (Instrument) |
305H x 230W x 45D mm “Tablet Style” |
| Weight (Instrument) |
2.7Kg |
| Dimensions (Carry Case) |
760mm x 420mm x 150mm |
| Weight (Full system including case) |
14.9Kg |
| Program Stores |
100, Location 1 loaded upon power up |
| Sweep Stores |
2000, all parameters in any sweep function |
| Remote Operation |
Full Capability, Control and Data |
| Operating Temperature |
-5 to 50ºC |
| Storage Temperature |
-10 to 60ºC |
| Relative Humidity Range |
20 to 90% Non-Condensing |
| IP Protection of Inputs and Outputs |
IP30 – CEI EN 60529 |
| Max Altitude |
2,000 Meters |
| Power Supply |
9-18V @ 3A, AC adapter or 12V dc from car or external batteries |
| Warranty |
3 Years |