High Accuracy 0.01dB 35MHz | PSM1735

High Accuracy 0.01dB 35MHz | PSM1735

High Accuracy 0.01dB 35MHz – Overview

Utilising an innovative design that incorporates both direct digital analysis and heterodyning techniques, the High Accuracy PSM1735 provides a broad range of measurement functions over a wider frequency range than any other instrument available today. Typical applications include switched-mode power supply feedback loop analysis, filter test, and design, LVDT testing, sweep frequency response analysis of wound components, and much more. The PSM1735 NumetriQ utilises the latest DSP and FPGA technology to optimise the use of its analogue hardware providing speed and measurement flexibility without compromising the performance of each measurement function. The N4L PSM1735 features 0.01dB gain accuracy, 0.02° phase accuracy, and a frequency range of up to 35 MHz.

High Accuracy 0.01dB 35MHz – Features 

  • Frequency range 10µHz to 35MHz
  • Floating differential inputs – 10 Vpk
  • Gain accuracy at < 1 kHz 0.01 dB
  • Phase accuracy at < 1 kHz 0.01°
  • Frequency response analyzer
  • Impedance analyzer
  • Vector Volt Meter / Phase Angle Volt Meter
  • RMS Volt Meter
  • Loop response analysis
  • Harmonic analyzer

Datasheet

Description

High Accuracy 0.01dB 35MHz PSM1735 Technical Specifications

High Accuracy 0.01dB 35MHz

MEASUREMENT SPECIFICATIONS
 
FREQUENCY RESPONSE ANALYSER
Measurement Magnitude | Gain (CH1/CH2 or CH2/CH1) | Gain (dB)
Offset Gain (dB) | Phase (º)
Frequency Range 10μHz to 35MHz
20mHz to 35MHz with External Source
Gain Accuracy in dB 0.01dB + 0.001dB/kHz < 1MHz
0.1dB + 0.04dB/MHz < 35MHz
Phase Accuracy 0.02⁰ < 10kHz
0.05⁰ + 0.0001⁰ / kHz < 35MHz
Frequency Source Generator | CH1 Input
Measurement Real-Time DFT | no missing data
Speed Up to 100 readings per second
Filter Selectable from 0.2 seconds
Resolution 5 or 6 digits
VECTOR VOLTMETER
Measurement In-Phase | Quadrature |
Tan Φ | Magnitude | Phase | In-Phase Ratio | RMS | RMS ratio,
LVDT Differential
LVDT Ratiometric
Frequency Range 10μHz to 35MHz
20mHz to 35MHz with External Source
Basic Accuracy (ac) 0.5% range + 0.05% reading + 0.05mV
LCR METER
Functions L | C | R (AC) | Q | Tan Delta | Impedance
phase – Series or Parallel circuit
Frequency Range 10μHz to 35MHz
Current Shunt External or N4L active head or
IAI (Impedance Analysis Interface)
LCR Measurement Functions
Resistance (R) 1mΩ to 500MΩ
Reactance (X) 1mΩ to 500MΩ
Impedance (Z) 1mΩ to 500MΩ
Capacitance Value (Cp & Cs) 1pF to 1mF
Phase Angle 0 to 360 deg with 0.001-degree resolution
Q. Factor +/- 0.00001 ~ 9999.99
Tan Delta (Reciprocal of Q, also known as Dissipation Factor D) +/- 0.00001 ~ 9999.99
Admittance (Y) reciprocal of impedance (Siemens) +/- 2nS to 1KS
Conductance (G) resistive part of admittance (Siemens) +/- 2nS to 1KS
Susceptance (B) reactive part of admittance (Siemens) +/- 2nS to 1KS
Voltage Bias +/- 10V
Ranges-LCR Head Inductance – 100nH to 10kH
Capacitance – 10pF to 1000μF
Resistance – 10mΩ to 100MΩ
Ranges-IAI Inductance – 10nH to 10kH
Capacitance – 1pF to 1000μF
Resistance – 1mΩ to 500MΩ
Basic Accuracy 0.1% + tolerance of selected current shunt
Sweep Capability All AC functions
IAI Impedance Analysis Interface
Frequency Range 10μHz to 35MHz
Basic Accuracy 0.1% <1kHz
0.2% + 0.0005% / kHz <35MHz
Internal Shunt Phase Accuracy Low 5Ω 0.1deg + 0.01deg / kHz
Normal 50Ω 0.05deg + 0.005deg / kHz
High 5kΩ 0.05deg + 0.005deg / kHz
Very High 500kΩ 0.1deg + 0.05deg / kHz
Power Source 90-264V RMS
47-64Hz
TRUE RMS VOLTMETER
Channels 2
Frequency Range DC to 1MHz
1MHz to 35MHz fundamental only
Measurement RMS | AC |DC | Peak | CF | Surge | dBm
Basic Accuracy (AC) As VVM + 0.05mV
Accuracy (DC) 0.01% VA range + 0.1% reading + 0.5mV
POWER METER
Measurements W | VA | PF | V | A | Total
Fundamental and Integrated | Power Harmonics
Frequency Range 20mHz to 1MHz
1MHz to 35MHz fundamental only
Current Shunt External or use an N4L power adaptor
Current Accuracy As Voltage + external shunt tolerance
Watts Accuracy 0.15% VA range + 0.15%
reading + external shunt tolerance
HARMONIC ANALYSER
Scan Single or Series
Frequency Range 10μHz to 1MHz
Measurement Harmonic |
series THD or difference THD
Max Harmonic 50
SYSTEM SPECIFICATIONS
INPUT RANGES
Inputs 2 Balanced Differential
Connectors Dual Grounded BNC
Coupling AC or AC+DC
Max Input 100Vpk from earth
Input Ranges 100V | 30V | 10V | 3V | 1V | 300mV | 100mV | 30mV | 10mVpk
Scaling 1 x 10^-9 to 1 x 10^9
Ranging Full auto | Up only or manual
Input Impedance 1M // 30pF (ex leads)
SIGNAL GENERATOR
Type Direct Digital Synthesis
Frequency 10μHz to 35MHz
Waveforms Sine | Square (1MHz)
Accuracy Open Loop (with no trim) Frequency ±0.05%
±10% < 10MHz
±20% < 35MHz
Accuracy Closed Loop (with trim) ±1% < 10MHz
±5% < 35MHz
Impedance 50Ω ±2%
Output Voltage(Open Circuit) 0V to ±10Vpk
Output Resolution 50μV to 5mV level dependant
Offset 0V to ±10Vpk
Offset Resolution ±10VmV
Clock Rate 150MHz
Connector Grounded BNC
DATALOG
Functions Up to 4 measured functions user selectable
Datalog Window From 10ms with no gap between each log
Memory RAM or non – volatile up to 8,000 records
HIGH-SPEED DATA STREAMING
Rate 1500 readings/s max
Window 660μs to 1s Synchronized to waveform
Buffer 8000 results
GENERAL
Display 320 x 240 dot LCD – white LED backlight
Alarm Any displayed function Hi | Lo | Inside Window |Outside Window
Program Stores 100, prog 1 loaded on power-up
Sweep Stores 30, all parameters in any sweep function
Remote Operation Full capability | Control, and data
Size 170H x 350W x 250D mm approx
Temperature 5 to 35°C
Weight 4Kg approx
Power Supply 90-264V RMS
47-63Hz
30VA max