FREQUENCY RESPONSE ANALYSER
|
|
| Measurement |
Magnitude | Gain (CH1/CH2 or CH2/CH1) | Gain (dB)
Offset Gain (dB) | Phase (º) |
| Frequency Range |
10μHz to 1MHz
20mHz to 500kHz with External Source |
| Gain Accuracy in dB |
0.02dB < 1kHz
0.05dB < 10kHz
0.1dB + 0.003⁰/kHz < 1MHz |
| Phase Accuracy |
0.02⁰ < 10kHz
0.02⁰ + 0.003⁰/kHz < 1MHz |
| Frequency Source |
Generator or CH1 Input |
| Measurement |
Real-Time DFT | No missing data |
| Speed |
Up to 100 readings per second |
| Filter |
Selectable from 0.2 seconds |
| Resolution |
5 or 6 digits |
VECTOR VOLTMETER
|
|
| Measurement |
In-Phase | Quadrature | Tan Φ | Magnitude |
Phase | In-Phase Ratio | rms | rms ratio
LVDT Differential
LVDT Ratiometric |
| Frequency Range |
10μHz to 1MHz
20mHz to 500kHz with External Source |
| Basic Accuracy (ac) |
0.05% range + 0.05% reading + 0.05mV < 1kHz
Basic + 0.02%/kHz < 10kHz
Basic + 0.2% + 0.002%/kHz < 1MHz |
LCR METER
|
|
| Functions |
L | C | R (AC) | Q | Tan delta | Impedance | phase – Series or Parallel circuit |
| Frequency Range |
10μHz to 1MHz |
| Current Shunt |
External or N4L active head or IAI (Impedance Analysis Interface) |
LCR Measurement Functions
|
|
| Resistance (R) |
1mΩ to 500MΩ |
| Reactance (X) |
1mΩ to 500MΩ |
| Impedance (Z) |
1mΩ to 500MΩ |
| Capacitance Value (Cp & Cs) |
1pF to 1mF |
| Phase Angle |
0 to 360 deg with 0.001-degree resolution |
| Q. Factor |
+/- 0.00001 ~ 9999.99 |
| Tan Delta (Reciprocal of Q, also known as Dissipation Factor D) |
+/- 0.00001 ~ 9999.99 |
| Admittance (Y) reciprocal of impedance (Siemens) |
+/- 2nS to 1KS |
| Conductance (G) resistive part of admittance (Siemens) |
+/- 2nS to 1KS |
| Susceptance (B) reactive part of admittance (Siemens) |
+/- 2nS to 1KS |
| Voltage Bias |
+/- 10V |
| Ranges – LCR Head |
Inductance – 100nH to 10kH
Capacitance – 10pF to 1000μF
Resistance – 10mΩ to 100MΩ |
| Ranges – IAI |
Inductance – 10nH to 10kH
Capacitance – 1pF to 1000μF
Resistance – 1mΩ to 500MΩ |
| Basic Accuracy |
0.1% + tolerance of selected current shunt |
| Sweep Capability |
All ac functions |
| Channels |
2 |
| Frequency Range |
DC to 1MHz |
| Measurement |
rms | AC | DC | Peak | CF | Surge | dBm |
| Basic Accuracy (AC) |
As VVM + 0.2mV |
| Accuracy (DC) |
0.1% range + 0.1% reading + 1mV |
IAI Impedance Analysis Interface
|
|
| Frequency Range |
DC to 1MHz |
| Basic Accuracy |
0.1% < 1kHz
0.2% + 0.002% / kHz < 1MHz |
| Internal Shunt Phase Accuracy |
Low 5Ω 0.1deg + 0.01deg / kHz
Normal 50Ω 0.05deg + 0.005deg / kHz
High 5kΩ 0.05deg + 0.005deg / kHz
Very High 500kΩ 0.1deg + 0.05deg / kHz |
| Power Source |
90-264V rms 47-64Hz |
POWER METER
|
|
| Measurements |
W | VA | PF | V | A | Total
Fundamental and Integrated | Power Harmonics |
| Frequency Range |
20mHz to 1MHz |
| Current Shunt |
External or use an N4L power adaptor |
| Current Accuracy |
As Voltage + external shunt tolerance |
| Watts Accuracy |
0.15% VA range + 0.15% reading + external shunt tolerance |
HARMONIC ANALYSER
|
|
| Scan |
Single or Series |
| Frequency Range |
10μHz to 1MHz |
| Measurement |
Harmonic |
series THD or difference THD |
| Max Harmonic |
50 |
SYSTEM SPECIFICATIONS
|
|
INPUT RANGES
|
|
| Inputs |
2 Differential |
| Connectors |
Isolated BNC |
| Coupling |
AC or AC+DC |
| Max Input |
100Vpk from earth |
| Input Ranges |
100V | 30V | 10V | 3V | 1V | 300mV | 100mV | 30mV | 10mVpk |
| Scaling |
1 x 10^-9 to 1 x 10^9 |
| Ranging |
Full auto | Up only or manual |
| Input Impedance |
1M // 50pF (exc leads) |
SIGNAL GENERATOR
|
|
| Type |
Direct Digital Synthesis |
| Frequency |
10μHz to 1MHz |
| Waveforms |
Sine | Triangle | Square | Sawtooth |
| Accuracy Open Loop (with no trim) |
Frequency ±0.05%±10% |
| Accuracy Closed Loop (with trim) |
±1% |
| Impedance |
50? ±2% |
| Output Voltage(Open Circuit) |
0V to ±10Vpk |
| Output Resolution |
5mV |
| Offset |
0V to ±10Vpk |
| Offset Resolution |
±10VmV |
| Clock Rate |
11.52MHz |
| Connector |
Grounded BNC |
DATALOG
|
|
| Functions |
Up to 4 measured functions user selectable |
| Datalog Window |
From 10ms with no gap between each log |
| Memory |
RAM or non – volatile up to 8,000 records |
HIGH-SPEED DATA STREAMING
|
|
| Rate |
1500 readings/s max |
| Window |
660μs to 1s Synchronized to waveform |
| Buffer |
8000 results |
GENERAL
|
|
| Display |
320 x 240 dot LCD – white LED backlight |
| Alarm |
Any displayed function Hi | Lo | Inside Window |Outside Window |
| Program Stores |
100, prog 1 loaded on power-up |
| Sweep Stores |
30, all parameters in any sweep function |
| Remote Operation |
Full capability | Control and data |
| Size |
170H x 350W x 250D mm approx |
| Temperature |
5 to 35°C |
| Weight |
4Kg approx |
| Power Supply |
90-264V rms
47-63Hz
30VA max |
Reviews
There are no reviews yet.