The High Accuracy Frequency Response Analyser PSM1700 is a comprehensive DFT and true RMS analysis instrument for R&D and production test applications. Specifically aimed at a range of gain/phase analysis applications, amongst which include switched-mode power supply feedback loop stability analysis and general frequency response analysis of filters. It has a clear, bright graphics display showing real-time values or graphs or tables. It can be operated by remote control over RS232 or LAN. When combined with the IAI (Impedance Analysis Interface) the PSM become a high accuracy 1MHz Impedance Analyzer/ LCR meter. It is designed to give optimum performance, speed of measurement, and convenience, providing sophisticated measurement capability. Cost-effective and an easy-to-use benchtop instrument.

High Accuracy FRA 100Vpk Input – Features

  • Frequency range 10µHz to 1MHz
  • Floating differential inputs – 100 Vpk
  • Gain accuracy at < 1 kHz 0.02 dB
  • Phase accuracy at < 1 kHz 0.02°
  • Frequency response analyser
  • Impedance analyser
  • Vector Volt Meter / Phase Angle Volt Meter
  • RMS Volt Meter
  • Loop response analysis
  • Harmonic analyser

Datasheet

Description

High Accuracy FRA 100Vpk Input PSM1700 Technical Specifications

High Accuracy FRA 100Vpk Input | PSM1700

MEASUREMENT SPECIFICATIONS

FREQUENCY RESPONSE ANALYSER
Measurement Magnitude | Gain (CH1/CH2 or CH2/CH1) | Gain (dB)
Offset Gain (dB) | Phase (º)
Frequency Range 10μHz to 1MHz
20mHz to 500kHz with External Source
Gain Accuracy in dB 0.02dB < 1kHz
0.05dB < 10kHz
0.1dB + 0.003⁰/kHz < 1MHz
Phase Accuracy 0.02⁰ < 10kHz
0.02⁰ + 0.003⁰/kHz < 1MHz
Frequency Source Generator or CH1 Input
Measurement Real-Time DFT | No missing data
Speed Up to 100 readings per second
Filter Selectable from 0.2 seconds
Resolution 5 or 6 digits
VECTOR VOLTMETER
Measurement In-Phase | Quadrature | Tan Φ | Magnitude |
Phase | In-Phase Ratio | rms | rms ratio
LVDT Differential
LVDT Ratiometric
Frequency Range 10μHz to 1MHz
20mHz to 500kHz with External Source
Basic Accuracy (ac) 0.05% range + 0.05% reading + 0.05mV < 1kHz
Basic + 0.02%/kHz < 10kHz
Basic + 0.2% + 0.002%/kHz < 1MHz
LCR METER
Functions L | C | R (AC) | Q | Tan delta | Impedance | phase – Series or Parallel circuit
Frequency Range 10μHz to 1MHz
Current Shunt External or N4L active head or IAI (Impedance Analysis Interface)
LCR Measurement Functions
Resistance (R) 1mΩ to 500MΩ
Reactance (X) 1mΩ to 500MΩ
Impedance (Z) 1mΩ to 500MΩ
Capacitance Value (Cp & Cs) 1pF to 1mF
Phase Angle 0 to 360 deg with 0.001-degree resolution
Q. Factor +/- 0.00001 ~ 9999.99
Tan Delta (Reciprocal of Q, also known as Dissipation Factor D) +/- 0.00001 ~ 9999.99
Admittance (Y) reciprocal of impedance (Siemens) +/- 2nS to 1KS
Conductance (G) resistive part of admittance (Siemens) +/- 2nS to 1KS
Susceptance (B) reactive part of admittance (Siemens) +/- 2nS to 1KS
Voltage Bias +/- 10V
Ranges – LCR Head Inductance – 100nH to 10kH
Capacitance  – 10pF to 1000μF
Resistance – 10mΩ to 100MΩ
Ranges – IAI Inductance – 10nH to 10kH
Capacitance – 1pF to 1000μF
Resistance – 1mΩ to 500MΩ
Basic Accuracy 0.1% + tolerance of selected current shunt
Sweep Capability All ac functions
Channels 2
Frequency Range DC to 1MHz
Measurement rms | AC | DC | Peak | CF | Surge | dBm
Basic Accuracy (AC) As VVM + 0.2mV
Accuracy (DC) 0.1% range + 0.1% reading + 1mV
IAI Impedance Analysis Interface
Frequency Range DC to 1MHz
Basic Accuracy 0.1% < 1kHz
0.2% + 0.002% / kHz < 1MHz
Internal Shunt Phase Accuracy Low 5Ω 0.1deg + 0.01deg / kHz
Normal 50Ω 0.05deg + 0.005deg / kHz
High 5kΩ 0.05deg + 0.005deg / kHz
Very High 500kΩ 0.1deg + 0.05deg / kHz
Power Source 90-264V rms 47-64Hz
POWER METER
Measurements W | VA | PF | V | A | Total
Fundamental and Integrated | Power Harmonics
Frequency Range 20mHz to 1MHz
Current Shunt External or use an N4L power adaptor
Current Accuracy As Voltage + external shunt tolerance
Watts Accuracy 0.15% VA range + 0.15% reading + external shunt tolerance
HARMONIC ANALYSER
Scan Single or Series
Frequency Range 10μHz to 1MHz
Measurement Harmonic |
series THD or difference THD
Max Harmonic 50
SYSTEM SPECIFICATIONS
INPUT RANGES
Inputs 2 Differential
Connectors Isolated BNC
Coupling AC or AC+DC
Max Input 100Vpk from earth
Input Ranges 100V | 30V | 10V | 3V | 1V | 300mV | 100mV | 30mV | 10mVpk
Scaling 1 x 10^-9 to 1 x 10^9
Ranging Full auto | Up only or manual
Input Impedance 1M // 50pF (exc leads)
SIGNAL GENERATOR
Type Direct Digital Synthesis
Frequency 10μHz to 1MHz
Waveforms Sine | Triangle | Square | Sawtooth
Accuracy Open Loop (with no trim) Frequency ±0.05%±10%
Accuracy Closed Loop (with trim) ±1%
Impedance 50? ±2%
Output Voltage(Open Circuit) 0V to ±10Vpk
Output Resolution 5mV
Offset 0V to ±10Vpk
Offset Resolution ±10VmV
Clock Rate 11.52MHz
Connector Grounded BNC
DATALOG
Functions Up to 4 measured functions user selectable
Datalog Window From 10ms with no gap between each log
Memory RAM or non – volatile up to 8,000 records
HIGH-SPEED DATA STREAMING
Rate 1500 readings/s max
Window 660μs to 1s Synchronized to waveform
Buffer 8000 results
GENERAL
Display 320 x 240 dot LCD – white LED backlight
Alarm Any displayed function Hi | Lo | Inside Window |Outside Window
Program Stores 100, prog 1 loaded on power-up
Sweep Stores 30, all parameters in any sweep function
Remote Operation Full capability | Control and data
Size 170H x 350W x 250D mm approx
Temperature 5 to 35°C
Weight 4Kg approx
Power Supply 90-264V rms
47-63Hz
30VA max