SIL2 Capable Oxygen Analyser | NTRON SILO2

SIL2 Capable Oxygen Analyser | NTRON SILO2

SIL2 Capable Oxygen Analyser  – Overview

Engineered for safety-critical environments across the chemical, pharmaceutical, and additive manufacturing sectors, this Process Oxygen Analyser delivers high-precision and uncompromising gas measurement. Its modular architecture pairs a compact control unit with a remote sensor, providing complete installation flexibility across demanding facility layouts. The installation is made even easier with the choice of three sensor mounting options: a flow-through base, TRI-Clamp or an ANSI 2” 150lbs flange. Its DIN rail-mounted control unit includes a galvanic barrier and remote electrochemical sensor with interconnecting cable (up to 30m), which provides a flexible, easily integrated package.

SIL2 Capable Oxygen Analyser  – Features

    • SIL2 Capable unit – Analyser and galvanic isolation barrier in one device
    • Measurement range: 0 to 25% O2
    • Push-button calibrations
    • 3 configurable alarm outputs
    • Compact for easy integration

Description

SIL2 Capable Oxygen Analyser | NTRON SILO2

Technical Specifications
Sensors
Solid State (S-S) OC-25/OC-25M OC-26/OC-26M OC-200 series
Measurement Range 0…25 %
Accuracy Please see Accuracy Table below
Output Resolution 0.01 %
Lower Detection Limit (LDL) 0.02 % +/- 0.01
Response Time (T90) <20 seconds, typically 12 seconds
Operating Temperature Range -20…+50 °C -20…+50 °C -20…+50 °C
Sample Flow Rate (application dependent) Flow-through/extractive: 100…500 ml/min (250 ml/min optimal) in a vented atmosphere
Direct insertion: Up to 6 m/s
Life Expectancy (application dependent) Up to 24 months Up to 24 months 12 months
Humidity 0…95 %rh non-condensing
Process Connection 2” Tri-clamp / Flow-through KF40 flange
Via Oxy Extract: 2” Tri-clamp/ANSI 150
Shelf Life 12 months 12 months Up to 6 months
Calibration Interval (application dependent) 6…12 months
Analyser
Electrical
Display LCD
Output Signal 4…20 mA
Digital Communication RS485 (not SIL-capable)
Relay Output Options 2 x configurable alarm relays, 1 x fault alarm relay, 1 x transistor
Power Supply 24 V DC
Relay Contact Outputs RL1 / RL2 / Alarm Switching power max.: 62.5 V A resp max. 30 W
Switching voltage: Um 125 V AC/110 V DC
Min. current 10 uA DC
Min. voltage 10 mV DC
According to IEC 947-5-1 resp. EN 60947
Transistor Output (DO) Switching parameters: < 28 V @ < 50 mA
Intrinsically Safe Connection Voltage Uo = 6 V DC
Current intensity Io = 0.2 mA
Power Po = 0.3 mW
Max. outer inductivity Lo = 1000 mH
Max. outer capacity Co = 10 μF
Maximum Power Consumption 1.5 W
Indicators LCD and LED alerts on analyser
Mechanical
Ingress Protection IP20 enclosure
Housing Material PBT
Mounting 35 mm DIN rail
Cable Length I.S sensor connection 5 m/10 m/15 m
Compliance cETLus: CAN/CSA-C22.2 No. 61010-1, UL-61010-1, EMC: EN 50270
Hazardous Area Classification ATEX:
II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC Tamb (-20 to +60 °C)

SIL2 Capable Oxygen Analyser | NTRON SILO2

Brand

Ntron

Ntron strives to exceed customer expectations by continually innovating better and more efficient gas analysis and control solutions to help maximise process efficiency, improve product quality, protect the health and safety of personnel and the environment, as well as preserve capital equipment and investments.