Tag: Electrical Testing

Electrical Testing

  • Leakage and Partial Discharge Acoustic Imager KUS-100

    Leakage and Partial Discharge Acoustic Imager | KUS-100

    R227,887.00 ex vat

    Leakage and Partial Discharge Acoustic Imager - Overview

    The KUS-100 acoustic imager has a built-in array of microphones which effectively detect sources of acoustic emission. This is extremely useful in industrial applications to detect leaks of compressed agents. It is also used to detect partial discharges in the power utility industry. This vital diagnostic tool enables significant savings by reducing energy losses. The imager operates in two detection modes: leakage and partial discharge. It can be manually tuned to the detected frequencies and the sensitivity level can be changed to avoid unwanted reflections and interference. Comfortable to use with an improved touch screen. A convenient strap is mounted to the housing.

    Leakage and Partial Discharge Acoustic Imager - Features

    • 2 detection modes
    • Leakage mode
    • Partial discharge mode
    • Touch screen
    • Manual tuning
  • Insulation Resistance Meter MIC-2511

    Insulation Resistance Meter | MIC-2511

    Price range: R25,272.00 through R52,647.00 ex vat

    Insulation Resistance Meter - Overview

    Measure insulation resistance up to 2 TΩ. The MIC-2511 may be used to measure the insulation resistance using test voltage up to 2500 V. This surprising tool includes numerous functions. Its parameters, robust casing (IP65 protection level), low battery power consumption, and the ability to recharge during measurements make it a reliable tool that can be used in many areas. The device has built-in help screens with measurement diagrams so you can easily and quickly check and make sure how to connect to a given system depending on the type of measurement performed. It is ideal for checking industrial installations and catenary networks and is also successfully used in residential buildings. It also enables the testing of surge protection devices (SPD). The advantages of this meter are especially appreciated by electricians working in maintenance, testing motors, cables and street lighting. It is also useful for measurements during the construction and maintenance of photovoltaic installations. It is a reliable solution created for the needs of telecommunications network installers and heating network operators, facilitating the control of the alarm system of pre-insulated pipes. Also available as an EPA kit.

    Insulation Resistance Meter - Features

    • Measurement voltage within the range of 10…2500 V: selected from 10 V, 25 V, 100 V, 250 V, 500 V, 1000 V, 2500 V, or 10…2500 V selected in steps of 10 V
    • Insulation resistance measurements with a voltage of 10 V of the supervisory loop of fire alarm systems
    • Charts plotted on display during measurements
    • Measurements in electrostatic protected areas (EPA)
    • Correction of insulation resistance result to reference temperature
    • Continuous reading of measured insulation resistance or leakage current
    • Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement
    • Sound signaling of five-second time intervals, facilitating capture of time characteristics
    • Timing of measurement times T1, T2 and T3 for measurement of one or two absorption coefficients (Ab1, Ab2 or DAR, PI) within the range of 1… 600 s
    • Automatic measurement of all resistance combinations of 3-, 4- and 5-core cords and power cords using the optional AutoISO-2511 adapter
    • Reading of actual measurement voltage during measurement
    • Measurement current <2 mA
    • Protection against measurement of live objects
    • Two- or three-lead method of insulation resistance measurement

    Additional features

    • Measurement of leakage current during measurement of RISO
    • Capacitance measurement during measurement of RISO
    • Low-voltage measurement of circuit continuity and resistance
    • Temperature measurement (with the use of the optional ST-1 temperature probe)
    • Measurement of direct and alternating voltages within the range of 0...1500 V
    • 9999-entry memory, data transmission to PC via USB cable
    • Power supplied by rechargeable battery
    • Backlit keyboard
    • The instrument meets the requirements laid down by standard EN IEC 61557

    https://www.youtube.com/watch?v=44SqibjYEl4

     

  • Thermal Imager KT-510

    Thermal Imager | KT-510

    R43,998.00 ex vat

    Thermal Imager - Overview

    The Kt-510 has a large display with innovative data processing electronics. It is protected by solid housing. The comfortable handle and easily accessible buttons ensure ergonomic operation which is optimal for professional and less experienced thermographers.Cameras are additionally equipped with visual lenses and related image-mixing technologies such as PIP, and MIF. Support from the built-in LED torch and laser improves operational quality by facilitating photography and image interpretation. The built-in report module allows for the preparation and printing of reports directly from the camera. Built-in communication interfaces ensure constant communication between the camera and the computer or mobile device over a wireless network. It offers full control and flexibility in various situations making it an ideal tool for both novices and professional thermographic inspectors.

    Thermal Imager - Features

    • Image files saved as JPG
    • Records IR videos (on SD memory card or computer hard disk)
    • Built-in reports module
    • MIF image combining mode
    • Extensive image analysis tools
    • Captures images within the visible light spectrum
    • Built-in: GPS, digital compass, LED flashlight, laser pointer, laser rangefinder
    • Interfaces: USB type C, Wi-Fi, Gigabit Ethernet, SD memory card slot, Bluetooth
    • Digital zoom
    • Interchangeable lenses do not require calibration by the manufacturer
  • Portable Electrical Equipment Safety Meter PAT-95

    Portable Electrical Equipment Safety Meter | PAT-95

    R58,100.00 ex vat

    Portable Electrical Equipment Safety Meter - Overview

    The PAT-95 is used for professionals involved in the maintenance and repair of power tools and appliances. Thanks to its accurate testing, it provides a detailed analysis of the technical condition of the equipment under examination. It ensures both the safety of users and the long-term maintenance of equipment. It is designed for both field and industrial challenges. It is ideally suited to situations where it is necessary to check power tools, three-phase devices and household appliances. The touch screen and auto-procedures section make testing quick and efficient. The automatic procedure wizard means even more flexibility for the instrument. The meter has a built-in help system. The meter works with a label printer and QR scanner, which facilitates record-keeping. It has initial measurement report printouts and QR code printouts available, which store unique data to identify the device in the database. It has compact and durable housing. It provides instrument protection during both measurements and transport.

    Portable Electrical Equipment Safety Meter  - Features

    • Power supply 195...265 V
    • Measurement of devices with 110 V and 230 V 50/60 Hz power supply
    • Measuring system that enables:
      • protective conductor resistance measurement
      • measurement of substitute, differential and touch leakage current
      • functional test
      • test of RCD and PRCD switches
      • ...and much more
    • Intuitive user interface
    • Works with a label printer and QR code scanner
  • EPA Zones Insulation Resistance Meter MIC-2511 EPA

    EPA Zones Insulation Resistance Meter | MIC-2511 EPA

    EPA Zones Insulation Resistance Meter  - Overview

    The Epa Zones Insulation Resistance Meter measures insulation resistance up to 2 TΩ / 2500V. It has robust casing with IP65 protection level. It has low battery power consumption and can be recharged during measurements.  The meter is both reliable and versatile. It is ideal for checking industrial installations, catenary networks, and residential buildings. Sought after by electricians working in maintenance, testing motors, cables and street lighting. It is also useful for measurements during construction and maintenance of photovoltaic installations. It is a reliable solution created for the needs of telecommunications network installers and heating network operators, facilitating the control of the alarm system of pre-insulated pipes.

    EPA Zones Insulation Resistance Meter - Features

    • Measurement of leakage current during measurement of RISO
    • Capacitance measurement during measurement of RISO
    • Low-voltage measurement of circuit continuity and resistance
    • Temperature measurement (with the use of the optional ST-1 temperature probe)
    • Measurement of direct and alternating voltages within the range of 0...1500 V
    • 9999-entry memory, data transmission to PC via USB cable
    • Power supplied by rechargeable battery
    • Backlit keyboard
    • The instrument meets the requirements laid down by standard EN IEC 61557
    • Measurement voltage within the range of 10…2500 V
    • Insulation resistance measurements with a voltage of 10 V of the supervisory loop of fire alarm systems
    • Testing surge protecting devices (SPD)
    • Charts plotted on display during measurements
    • Measurements in electrostatic protected areas (EPA)
    • Correction of insulation resistance result to reference temperature
    • Continuous reading of measured insulation resistance or leakage current
    • Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement
    • Sound signaling of five-second time intervals
    • Timing of measurement times T1, T2 and T3 for measurement of one or two absorption coefficients (Ab1, Ab2 or DAR, PI) within the range of 1… 600 s
    • Automatic measurement of all resistance combinations of 3-, 4- and 5-core cords and power cords by means of the optional AutoISO-2511 adapter
    • Reading of actual measurement voltage during measurement
    • Measurement current <2 mA
    • Protection against measurement of live objects
    • Two- or three-lead method of insulation resistance measurement
  • Impedance Analysis Package 10uHz ~ 35MHz IAI

    Impedance Analysis Package 10uHz ~ 35MHz | IAI + PSM1700

    Impedance Analysis Package - Overview

    The Impedance Analysis Interface is an optional measurement interface intended to be used with the PSM1700 and PSM1735 to form a high-accuracy Impedance Analyser. The IAI provides all of the functionality of the LCR Active Head but with a wider frequency and impedance measurement range plus higher nominal accuracy. This is achieved by a more sophisticated design that includes an additional internal shunt range, a current amplifier to increase low impedance signal levels and calibration together with the PSM1700/PSM1735 with which it will be used. Applications include passive component analysis and detailed wideband characterisation (capacitors, inductors and resistors), material analysis (corrosion, surface finish analysis etc), electrochemical impedance analysis (battery/cell as well as general electrochemistry), biomedical applications, cable impedance measurements and Input/Output Impedance Measurement of Sub Circuits.

    Impedance Analysis Package - Features

    • Wide Frequency Range
    • Wide Impedance Range
    • High phase accuracy
    • Excellent Impedance accuracy
    • Ability to control remotely
    • Highly selective DFT analysis
    • Flexible features
    • Full graphical display
    • Automatic range switching
    • 4-wire Kelvin Connections
    • DC to 35MHz frequency range
    • Signal level: ±10V peak max.
    • Shunts: 5Ω, 50Ω, 5kΩ, 500kΩ

     

     

  • Impedance Analysis Package 10uHz ~ 50MHz IAI2 + PSM3750

    Impedance Analysis Package 10uHz ~ 50MHz | IAI2 + PSM3750

    Impedance Analysis Package - Overview

    The IAI2 converts the PSM3750 units into high-performance LCR meters with true 4-wire Kelvin connections that are taken directly to the component without the need for external shunts. Buffering, amplification, and selectable shunts provide LCR measurements over a wide frequency and impedance range. This Impedance Analyzer allows for a wider frequency and impedance measurement range plus higher nominal accuracy. The IAI2 features 4 internal shunts plus an internal high-frequency amplifier. The combination of the PSM3750 and the IAI2 offers a comprehensive measurement suite. Applications include passive component analysis and detailed wideband characterization (capacitors, inductors and resistors), material analysis (corrosion, surface finish analysis etc), electrochemical impedance analysis (battery/cell as well as general electrochemistry), biomedical applications, cable impedance measurements and input/output impedance measurement of sub-circuits.

    Impedance Analysis Package - Features

    • 4-wire Kelvin Connections
    • DC to 50MHz frequency range
    • Signal level: ±10V peak max.
    • Shunts: 5Ω, 50Ω, 5kΩ, 500kΩ