CO2 Transmitter | GS07

CO2 Transmitter | GS07

Price range: R4,152.00 through R5,543.00 ex vat

CO2 Transmitter – Overview

The GS07 is a state-of-the-art non-dispersive infrared (NDIR) carbon dioxide transmitter. The direct insertion design and miniature size make it easy to install into a ventilation duct. It provides measurement in analogue outputs (0 … 10 V, 4 … 20 mA) and digital output (RS-485 Modbus RTU protocol). It helps to save money by decreasing energy consumption while maintaining a healthier indoor climate for CO2 demand-controlled ventilation.

CO2 Transmitter – Features

  • Patented non-dispersive infrared (NDIR) waveguide technology
  • Reliable measurements
  • Complies with EMC directive 2014 / 30 / EU
  • CO2 Measuring range:0 … 2,000 / 0 … 5,000 / 0 … 20,000 (PPM) (Max.:50,000 PPM)
  • IP rating: IP65
  • Digital output (RS-485 Modbus RTU protocol)
  • Analog output (0 … 10 V, 4 … 20 mA)
  • Virtually maintenance-free in most HVAC ventilation applications
  • High tolerance to extreme humidity environment conditions
  • Non-frill design, direct DDC connection

 

Description

CO2 Transmitter | GS07

Specification
CO2 Measuring range 0 … 2,000 / 0 … 5,000 / 0 … 20,000 (PPM) (Max.:50,000 PPM)
Output
RS-485 Digital output with Modbus RTU protocol
Voltage signal terminal CO2 Note3 Voltage or current output: Jumper selection (Default 0 … 10 V)
Vo linear conversion range: DC 0 … 10 V for 0 … 2000 PPMvol.
Io linear conversion range:4 … 20 mA for 0 … 2000 PPMvol.
D/A resolution:10 bits (10 mV / 0.016 mA)
D/A conversion accuracy:±2% of reading±50 mV
Electrical characteristics: Voltage output-ROUT<100 Ω, RLOAD>5 kΩ
Current output-RLOAD<500 Ω
Operating temperature range 0 … 50°C
Storage temperature range -40 … +70°C
Operating humidity range 0 … 100% RH (Sensor in powered-up condition)
Operating environment Residential, commercial and industrial spaces Note 1
Warm-up time ≦1 min(at full specs≦15 min)
Sensor life expectancy >15 years
Duct air velocity Direct insertion sensor, no minimum airs peed requirement
Maintenance interval No maintenance Note 2 (with ABC algorithm)
Power input AC / DC 24 V±20%, 50 Hz or 60Hz (Half-wave rectifier input)
Power consumption <1 W average
Connection wires 3×22 AWG cables for power input (G+, G0)& voltage / Current output (Out)
Connection screw terminal 4×1.0 mm2 for power input (G+, G0), RS-485 output (A, B)
Sensing method Non-dispersive infrared (NDIR) waveguide technology with
Automatic Background Calibration (ABC)and passive gas diffusion (No moving parts)
Response time(T1/e) <10 sec (at 30 cc/min flow rate)/ <3 min diffusion time
Repeatability ±30 PPM±1% of reading
Accuracy Note 1,2 ±40 PPM±3% of reading (at 25°C)
Annual zero drift Note 1,2 <±10 PPM (with ABC function)
Pressure dependence +1.6% reading per hPa
Installation support Background level calibration adjustment jumper trigger (bCAL)
Dimension 94×30 mm diameter
Duct probe length 51 mm
IP rating IP65
Compliance with EMC directive 2014 / 30 / EU

Note 1: The SO2 enriched environments are excluded.
Note 2: In normal IAQ applications(at NTP). Accuracy is defined after a minimum of 3 weeks of continuous operation. The tolerance of the span calibration gas (2% unless otherwise requested)and test gas adds to the total uncertainty.
Note 3: The specifications are valid for the output load connected to ground G0. Other outputs and measurement ranges are available
per request.

CO2 Transmitter | GS07

Additional information

Options:

4-20mA, 2000PPM, Clamp, 4-20mA, 5000PPM, Clamp, 4-20mA,10000PPM, Clamp, 4-20mA, 20000PPM, Clamp

Brand

eYc

Reviews

There are no reviews yet.

Be the first to review “CO2 Transmitter | GS07”